Connectors, Switches, Security Override Jumper and Status LED Indicators
Compaq ProLiant DL360 Generation 2 Server Maintenance and Service Guide
5-13
COMPAQ CONFIDENTIAL
Codename: Maisto Part Number: 233831-001 Last Saved On: 12/12/01 10:24 AM
Table 5-9: Hot-Plug Hard Drive LED Indicator Status Combinations
Activity Online Fault
Condition
On Off Off
Do not remove the drive. Removing a drive during this
process will cause data loss.
The drive is being accessed and is not configured as part
of an array.
On Flashing
Off
Do not remove the drive. Removing a drive during this
process will cause data loss.
The drive is rebuilding or undergoing capacity expansion.
Flashing Flashing Flashing
Do not remove the drive. Removing a drive during this
process will cause data loss.
The drive is part of an array being selected by the Array
Configuration Utility.
-Or-
The Options ROMPaq is upgrading the drive.
Off
Off
Off
OK to replace the drive online if a predictive failure alert is
received and the drive is attached to an array controller.
The drive is not configured as part of an array.
-Or-
If this drive is part of an array, then a powered-on controller
is not accessing the drive.
-Or-
The drive is configured as an online spare.
Off
Off
On
OK to replace the drive online.
The drive has failed, and has been placed off-line.
Off
On
Off
OK to replace the drive online if a predictive failure alert is
received, provided that the array is configured for fault
tolerance and all other drives in the array are online.
The drive is online and configured as part of an array.
On or
Flashing
On
Off
OK to replace the drive online if a predictive failure alert is
received, provided that the array is configured for fault
tolerance and all other drives in the array are online.
The drive is online and being accessed.