Removal and Replacement Procedures
2-4
Compaq ProLiant DL360 Generation 2 Server Maintenance and Service Guide
COMPAQ CONFIDENTIAL
Codename: Maisto Part Number: 233831-001 Last Saved On: 12/12/01 3:47 PM
Preparation Procedures
Before removing any serviceable parts, determine whether the part is a hot-plug device or a
non-hot-plug device.
Hot-Plug Devices
The only hot-plug devices on Compaq ProLiant DL360 Generation 2 servers are the SCSI
hard drives. SCSI hard drives can be serviced without removing the server from the rack.
IMPORTANT:
It is not necessary to turn off the server to replace hot-plug hard drives when they are
not in active use.
Non-Hot-Plug Devices
The CD-ROM drive can be replaced with the server power in standby mode. The CD-ROM
drive can be replaced without the need to remove the server from the rack.
To service all other non-hot plug devices, the server must be powered down completely by
removing the power cord. To service all other non-hot-plug devices the server must be
removed from the rack and the access panel removed after completely powering down the
server.