Removal and Replacement Procedures
2-26
Compaq ProLiant DL360 Generation 2 Server Maintenance and Service Guide
COMPAQ CONFIDENTIAL
Codename: Maisto Part Number: 233831-001 Last Saved On: 12/12/01 3:47 PM
Power Supply
To remove the power supply:
1. Power down the server. See “Powering Down the Server” in this chapter.
2. Remove the server from the rack. See “Removing the Server from the Rack” in this
chapter.
3. Remove the access panel. See “Server Access Panel” in this chapter.
4. Remove the PCI riser board assembly. See “PCI Riser Board Assembly” in this chapter.
5. Remove the air baffle. See “Air Baffle” in this chapter.
6. Remove the AC power cord and filter. See “AC Power Cord and Filter” in this chapter.
7. Release the AC power cord from its routing clips.
8. Lift the power supply retaining latch
.
9. Slide the power supply toward the outside edge of the server until it disengages from the
system board connector
.
10. Tilt the outside edge of the power supply upward and lift to remove it from the chassis
.
3
2
1
Figure 2-23: Removing the power supply
Reverse steps 1 through 10 to replace the power supply, aligning the pins with the system