background image

G:\Masters\Installation Sheets\AdBlue\AdBlue Laser Installation Sheet.doc 

Page 3 of 23 

1. 

Conditions of use 

 

Read  this  manual  completely  before  working  on  or  making  adjustments  to  the  Compac 
equipment. 

 

Compac  Industries  Limited  accepts  no  liability  for  personal  injury  or  property  damage  resulting 
from working on or adjusting this unit incorrectly or without authorisation.  

 

Along with any warnings, instructions, and procedures in this manual, you should also observe 
any other common sense procedures that are generally applicable to equipment of this type. 

 

Failure  to  comply  with  any  warnings,  instructions,  procedures,  or  any  other  common  sense 
procedures  may  result  in  injury,  equipment  damage,  property  damage,  or  poor  performance  of 
the Compac equipment 

 

The major hazard involved with installing and operating the unit is electrical shock. This hazard 
can be avoided if you adhere to the procedures in this manual and exercise all due care. 

 

Compac  Industries  Limited  accepts  no  liability  for  direct,  indirect,  incidental,  special,  or 
consequential  damages  resulting  from  failure  to  follow  any  warnings,  instructions,  and 
procedures  in  this  manual,  or  any  other  common  sense  procedures  generally  applicable  to 
equipment of this type. The foregoing limitation extends to damages to person or property caused 
by the unit or damages resulting from the inability to use the unit including loss of profits, loss of 
products,  loss  of  power  supply,  the  cost  of  arranging  an  alternative  power  supply,  and  loss  of 
time, whether incurred by the user or their employees, the installer, the commissioner, a service 
technician, or any third party.  

 

Compac Industries Limited reserves the right to change the specifications of its products or the 
information in this manual without necessarily notifying its users. 

 

Variations  in  installation  and  operating  conditions  may  affect  the  unit's  performance.  Compac 
Industries Limited has no control over each installation's unique operating environment. Hence, 
Compac Industries Limited makes no representations or warranties concerning the performance 
of the unit under the actual operating conditions prevailing at the installation. A technical expert of 
your choosing should validate all operating parameters for each application. 

 

Compac Industries Limited has made every effort to explain all servicing procedures, warnings, 
and  safety  precautions  as  clearly  and  completely  as  possible.  However,  due  to  the  range  of 
operating environments, it is not possible to anticipate every issue that may arise. This manual is 
intended to provide general guidance. For specific guidance and technical support, contact your 
authorised Compac supplier, using the contact details in the Product Identification section 

 

Only parts supplied by or approved by Compac may be used and no unauthorised modifications to 
the hardware of software may be made. The use of non-approved parts or modifications will void 
all warranties and approvals. The use of non-approved parts or modifications may also constitute 
a safety hazard. 

 

Information  in  this  manual  shall  not  be  deemed  a  warranty,  representation,  or  guarantee.  For 
warranty provisions applicable to this unit, please refer to the warranty provided by the supplier. 

 

Unless otherwise noted, references to brand names, product names, or trademarks constitute the 
intellectual property of the owner thereof. Subject to your right to use the unit, Compac does not 
convey any right, title, or interest in its intellectual property, including and without limitation, its 
patents, copyrights, and know-how.  

 

Every effort has been made  to ensure the accuracy of this document. However, it may contain 
technical  inaccuracies  or  typographical  errors.  Compac  Industries  Limited  assumes  no 
responsibility  for  and  disclaims  all  liability  of  such  inaccuracies,  errors  or  omissions  in  this 
publication. 

 

Note:  This  Installation  Sheet  is  for  the  current  model  Laser  V2  Mk2  series  dispensers.  If 
you are relocating an older model, please refer to Compac for specific footprint drawings.

 

 

Содержание Laser AdBlue LA 30-160SD

Страница 1: ...l Laser AdBlue Dispenser Version LA 30S LLA 30S AdBlue duo LLA 30S AdBlue duo nozzles on same end LLA 30 40S AdBlue diesel duo LA 30 40SD AdBlue diesel lane specific LLA 30 40SQ AdBlue diesel quad LLA...

Страница 2: ...p switch settings 13 10 1 Standard Pump Comms Setting 13 10 2 Gilbarco Pump comms Setting 13 11 Triac Dip switches 13 12 Electrical Operation Test 14 13 Mechanical Commissioning and Air Purge 15 14 Se...

Страница 3: ...has no control over each installation s unique operating environment Hence Compac Industries Limited makes no representations or warranties concerning the performance of the unit under the actual ope...

Страница 4: ...transit in particular damage to electronics due to vibration or jarring All terminals and plugs should be checked including IC chips to ensure they are securely in place 4 AdBlue pump specifications E...

Страница 5: ...Where local regulations for flammable substances require a sump to be fitted a Sumps must be provided at all dispenser installations with secondary containment pipework and at all new installations an...

Страница 6: ...G Masters Installation Sheets AdBlue AdBlue Laser Installation Sheet doc Page 6 of 23 7 Footprints 7 1 LLA 30S two hose with nozzles on opposite ends...

Страница 7: ...G Masters Installation Sheets AdBlue AdBlue Laser Installation Sheet doc Page 7 of 23 7 2 LLA 30S Duo two hose with nozzles on same end...

Страница 8: ...G Masters Installation Sheets AdBlue AdBlue Laser Installation Sheet doc Page 8 of 23 7 3 LA 30S...

Страница 9: ...G Masters Installation Sheets AdBlue AdBlue Laser Installation Sheet doc Page 9 of 23 7 4 LA30 40SD LA30 80SD LLA30 40S LLA30 80S...

Страница 10: ...G Masters Installation Sheets AdBlue AdBlue Laser Installation Sheet doc Page 10 of 23 7 5 LA 30 160SD LLA 30 160S...

Страница 11: ...G Masters Installation Sheets AdBlue AdBlue Laser Installation Sheet doc Page 11 of 23 7 6 LLA 30 40SQ LLA30 80SQ LLA30 160SQ...

Страница 12: ...s Electrical cables are terminated at the C4000 Power Supply which is housed in the Flameproof Enclosure located in the bottom of the dispenser behind the door The incoming cables are terminated as sh...

Страница 13: ...3 ON 4 OFF These are factory set to the standard setting unless ordered otherwise eg Gilbarco 10 2 Gilbarco Pump comms Setting Special software and interface board required 1 OFF 2 ON 3 OFF 4 ON 11 T...

Страница 14: ...olenoids will energise starting the pump motor Check that Diodes D8 D10 and D11 turn on indicating a signal is being sent to the triacs to open the solenoid valves 8 The diagnostic LED D18 flashes qui...

Страница 15: ...transaction and continue delivering AdBlue 9 Repeat steps 4 through 6 until the AdBlue flows without any air being present then hang the nozzle 10 Remove the dummy encoder plug and re install the V40...

Страница 16: ...ose For a single hose only Pn will appear 14 3 2 Setting the Price Using the Parameter Switch follow the chart to set the price for the hose s in question Step ACTION RESULT 1 Ensure that the nozzle i...

Страница 17: ...14 Not used J3 Input from meter side A J9 Power for meters J15 Not used J4 Input from meter side B J10 Totes J16 Not used J5 Not used J11 Buzzer J17 Backlighting J6 Not used J12 Nozzle Switches Connec...

Страница 18: ...ser into a certified measuring container and compare the display value with the amount dispensed Example Display shows 10 00 True volume 20 00 To calculate the correct K Factor from the information ab...

Страница 19: ...n on again For unattended refuelling sites the dispensers should not be able to work in stand alone mode in the event of a controller failure Therefore the dispenser should be set up to inhibit standa...

Страница 20: ...Laser Installation Sheet doc Page 20 of 23 18 2 ZVA AdBlue Nozzle The ZVA AdBlue nozzle with a magnetic safety catch is commonly used on AdBlue dispensers The following image is included for reference...

Страница 21: ...ioner Although generators are fitted with power regulators most are not filtered sufficiently for powering sensitive electrical components We recommend installing a commercial power conditioner and or...

Страница 22: ...ice agent contact details Use this information when contacting service agent or help desk Model number Serial number Date of manufacture Date of installation Software version Equipment connected to th...

Страница 23: ...co nz Copyright 2014 Compac Industries Limited All Rights Reserved Contact your service agent in the first instance for any installation issues 26 Revision History Previous revision date Summary of ch...

Отзывы: