G:\Masters\Installation Sheets\AdBlue\AdBlue Laser Installation Sheet.doc
Page 21 of 23
19.
Error Messages
Error Code
Fault
Action
Err 3
No price or pump number set.
Set the pump number or:
Set a price at the pump or at
the controller.
Err 7
Excess flow.
Max Flowrate exceeded
Err 8
Excess reverse rotation of encoder.
Check product is not flowing
back into the tank once the
delivery has finished.
Err 9
Faulty or disconnected meter encoder.
1.
Check that encoder is
plugged in.
2.
Replace encoder PCB on
meter
Err 10
Configuration Lost
Reconfigure C4000 refer to
C4000 manual
Err 12
C4000 memory failure.
Change memory IC.
F-AD-DS1225 (not applicable
to Futra)
Ped
Abd
Display error
1.
Check display cable for
loose wires/crimps
2.
Replace display PCB
20.
Precautions if Using Generator Power
The power output from onsite generators can cause power spikes that may damage electrical
components within the cabinet. When connecting to sites powered by generators, please take
the following precautions:
1)
Install a power conditioner. Although generators are fitted with power regulators, most are
not filtered sufficiently for powering sensitive electrical components. We recommend
installing a commercial power conditioner and/or UPS between the generator and the unit.
2)
Starting up. Before starting a generator, make sure the power to the unit is turned off.
Start the generator, let the generator reach stable operating speed and wait 30 seconds
before reconnecting the power to the unit.
3)
For units where the generator starts and stops on demand, install a delay timer or PLC to
automatically isolate the unit until the operating speed and consistent power output is
achieved.
4)
Isolate the unit before shutting down the generator.
21.
AdBlue Dispenser Spare Parts
This spare parts list only covers parts specific to Adblue dispensers. For all other major parts
please refer to the C4000 Master manual.
Part Number
Description
F-D-METER-KG
KG V40 Mass flow meter
F-G-SS8-IMC-12V
KG meter inlet tube fitting with Viton oring
F-GSKT-O/C-25V
Pipe outlet gasket with 25mm hole
F-GSKT-SF901V
Viton solenoid flange gasket
F-SOLND-3/4AB
3/4" solenoid with viton seals for Adblue use
F-CU-ENC-ABL-PT
Encoder dummy plug used for air purge and testing