G:\Masters\Installation Sheets\AdBlue\AdBlue Laser Installation Sheet.doc 

Page 21 of 23 

19. 

Error Messages 

 
 

Error Code

 

Fault

 

Action

 

Err 3 

No price or pump number set. 

Set the pump number or: 
Set a price at the pump or at 
the controller. 

Err 7  

Excess flow. 

Max Flowrate exceeded 

Err 8  

Excess reverse rotation of encoder. 

Check product is not flowing 
back into the tank once the 
delivery has finished. 

Err 9 

Faulty or disconnected meter encoder. 

1.

 

Check that encoder is 
plugged in. 

2.

 

Replace encoder PCB on 
meter 

Err 10 

Configuration Lost 

Reconfigure C4000 refer to 
C4000 manual 

Err 12 

C4000 memory failure. 

Change memory IC. 
F-AD-DS1225 (not applicable 
to Futra) 

Ped  
Abd 

Display error 

1.

 

Check display cable for 
loose wires/crimps 

2.

 

Replace display PCB 

 

20. 

Precautions if Using Generator Power 

The power output from onsite generators can cause power spikes that may damage electrical 
components within the cabinet. When connecting to sites powered by generators, please take 
the following precautions: 
1)

 

Install a power conditioner. Although generators are fitted with power regulators, most are 

not  filtered  sufficiently  for  powering  sensitive  electrical  components.  We  recommend 
installing a commercial power conditioner and/or UPS between the generator and the unit. 

2)

 

Starting up. Before starting a generator, make sure the power to the unit is turned off.  

Start  the  generator,  let  the  generator  reach  stable  operating  speed  and  wait  30  seconds 
before reconnecting the power to the unit. 

3)

 

For units where the generator starts and stops on demand, install a delay timer or PLC to 

automatically  isolate  the  unit  until  the  operating  speed  and  consistent  power  output  is 
achieved. 

4)

 

Isolate the unit before shutting down the generator. 

21. 

AdBlue Dispenser Spare Parts 

This spare parts list only covers parts specific to Adblue dispensers. For all other major parts 
please refer to the C4000 Master manual. 

 

Part Number

 

Description

 

F-D-METER-KG 

KG V40 Mass flow meter 

F-G-SS8-IMC-12V 

KG meter inlet tube fitting with Viton oring 

F-GSKT-O/C-25V 

Pipe outlet gasket with 25mm hole 

F-GSKT-SF901V 

Viton solenoid flange gasket 

F-SOLND-3/4AB 

3/4" solenoid with viton seals for Adblue use 

F-CU-ENC-ABL-PT 

Encoder dummy plug used for air purge and testing 

Содержание Laser AdBlue LA 30-160SD

Страница 1: ...l Laser AdBlue Dispenser Version LA 30S LLA 30S AdBlue duo LLA 30S AdBlue duo nozzles on same end LLA 30 40S AdBlue diesel duo LA 30 40SD AdBlue diesel lane specific LLA 30 40SQ AdBlue diesel quad LLA...

Страница 2: ...p switch settings 13 10 1 Standard Pump Comms Setting 13 10 2 Gilbarco Pump comms Setting 13 11 Triac Dip switches 13 12 Electrical Operation Test 14 13 Mechanical Commissioning and Air Purge 15 14 Se...

Страница 3: ...has no control over each installation s unique operating environment Hence Compac Industries Limited makes no representations or warranties concerning the performance of the unit under the actual ope...

Страница 4: ...transit in particular damage to electronics due to vibration or jarring All terminals and plugs should be checked including IC chips to ensure they are securely in place 4 AdBlue pump specifications E...

Страница 5: ...Where local regulations for flammable substances require a sump to be fitted a Sumps must be provided at all dispenser installations with secondary containment pipework and at all new installations an...

Страница 6: ...G Masters Installation Sheets AdBlue AdBlue Laser Installation Sheet doc Page 6 of 23 7 Footprints 7 1 LLA 30S two hose with nozzles on opposite ends...

Страница 7: ...G Masters Installation Sheets AdBlue AdBlue Laser Installation Sheet doc Page 7 of 23 7 2 LLA 30S Duo two hose with nozzles on same end...

Страница 8: ...G Masters Installation Sheets AdBlue AdBlue Laser Installation Sheet doc Page 8 of 23 7 3 LA 30S...

Страница 9: ...G Masters Installation Sheets AdBlue AdBlue Laser Installation Sheet doc Page 9 of 23 7 4 LA30 40SD LA30 80SD LLA30 40S LLA30 80S...

Страница 10: ...G Masters Installation Sheets AdBlue AdBlue Laser Installation Sheet doc Page 10 of 23 7 5 LA 30 160SD LLA 30 160S...

Страница 11: ...G Masters Installation Sheets AdBlue AdBlue Laser Installation Sheet doc Page 11 of 23 7 6 LLA 30 40SQ LLA30 80SQ LLA30 160SQ...

Страница 12: ...s Electrical cables are terminated at the C4000 Power Supply which is housed in the Flameproof Enclosure located in the bottom of the dispenser behind the door The incoming cables are terminated as sh...

Страница 13: ...3 ON 4 OFF These are factory set to the standard setting unless ordered otherwise eg Gilbarco 10 2 Gilbarco Pump comms Setting Special software and interface board required 1 OFF 2 ON 3 OFF 4 ON 11 T...

Страница 14: ...olenoids will energise starting the pump motor Check that Diodes D8 D10 and D11 turn on indicating a signal is being sent to the triacs to open the solenoid valves 8 The diagnostic LED D18 flashes qui...

Страница 15: ...transaction and continue delivering AdBlue 9 Repeat steps 4 through 6 until the AdBlue flows without any air being present then hang the nozzle 10 Remove the dummy encoder plug and re install the V40...

Страница 16: ...ose For a single hose only Pn will appear 14 3 2 Setting the Price Using the Parameter Switch follow the chart to set the price for the hose s in question Step ACTION RESULT 1 Ensure that the nozzle i...

Страница 17: ...14 Not used J3 Input from meter side A J9 Power for meters J15 Not used J4 Input from meter side B J10 Totes J16 Not used J5 Not used J11 Buzzer J17 Backlighting J6 Not used J12 Nozzle Switches Connec...

Страница 18: ...ser into a certified measuring container and compare the display value with the amount dispensed Example Display shows 10 00 True volume 20 00 To calculate the correct K Factor from the information ab...

Страница 19: ...n on again For unattended refuelling sites the dispensers should not be able to work in stand alone mode in the event of a controller failure Therefore the dispenser should be set up to inhibit standa...

Страница 20: ...Laser Installation Sheet doc Page 20 of 23 18 2 ZVA AdBlue Nozzle The ZVA AdBlue nozzle with a magnetic safety catch is commonly used on AdBlue dispensers The following image is included for reference...

Страница 21: ...ioner Although generators are fitted with power regulators most are not filtered sufficiently for powering sensitive electrical components We recommend installing a commercial power conditioner and or...

Страница 22: ...ice agent contact details Use this information when contacting service agent or help desk Model number Serial number Date of manufacture Date of installation Software version Equipment connected to th...

Страница 23: ...co nz Copyright 2014 Compac Industries Limited All Rights Reserved Contact your service agent in the first instance for any installation issues 26 Revision History Previous revision date Summary of ch...

Отзывы: