ADJUSTING THE SQUEEGEE BODY RUBBER BLADES
Careful adjustment of the squeegee body rubber blades guarantees better cleaning of the floor.
To adjust the squeegee body blades, proceed as follows:
1.
Select the i-drive program “transport” by rotating the knob to position “A” as shown in (
Fig.1
).
N.B.
: by rotating the i-drive selector to the transfer program, all the brush heads and the squeegee
body will move to their idle positions (raised off floor).
N.B.
: on the screen of the command display, the machine silhouette will have a green icon only
the symbol that identifies the traction motor
.
2. Take the machine to the maintenance area.
NOTE
: the place designated for this operation must comply with current environmental protection
regulations.
3.
Shift the direction lever (1) to “idle”, moving it in the direction shown by the arrow (
Fig.2
).
N.B.
: to select idle (N) move the lever in the direction shown by the arrow (
Fig.2
).
N.B.
: the letter “N” will appear on the command display indicating that no gear is engaged.
4.
Engage the parking brake by moving the parking brake lever (2), beside the operator's seat, in the
direction shown by the arrow (
Fig.3
).
N.B.
: the symbol regarding the parking brake being engaged will appear on the command
display.
5.
Select the i-drive program “scrubbing with drying” by rotating the knob to position “C” as shown in
(
Fig.1
).
N.B.
: rotating the i-drive selector to the scrubbing with drying program, all the brush heads and
squeegee body will move to their working positions (in contact with the floor).
6.
Press the drive pedal (3) to move both the squeegee body and the brush head bodies to their
working positions (
Fig.4
).
N.B.
: on the screen of the command display, the machine silhouette will have a green icon:
the symbol that identifies the traction motor; the symbols that identify the motors of the
scrubbing brush head; the symbols that identify the motor of the sweeping brush head; the
symbols that identify the vacuum motors.
7. As soon as the brush head and splash guard bars are in the working position, make sure the
machine is in a safe condition (read “
”).
CAUTION
: these operations must be carried out using protective gloves to avoid any possible
contact with the edges or tips of metal objects.
8. Stand at the back of the machine.
9.
Use the appropriate tool to loosen the nut (4) that holds the adjustment screw (5) in place (
Fig.5
).
N.B.
: the equipment to be used for this operation is not supplied with the machine.
10.
To adjust the central part of the splash guard rubber, turn the adjustment pin (5) until the splash
guard rubber is evenly folded outwards along the entire length by about 30°- 45° with respect to
the floor (
Fig.6
).
11.
To adjust the outer part of the splash guard rubber, loosen the knob (6) and screw in or unscrew
the pin (7) until the splash guard rubber is evenly folded outwards along the entire length by about
30°- 45° with respect to the floor (
Fig.7
).
ATTENTION
: the right-hand and left-hand knobs must be
rotated the same number of times, so that the
squeegee is parallel to the floor when it is working.
DISPOSAL
To dispose of the machine, take it to a demolition centre or an authorised
collection centre. Before scrapping the machine, it is necessary to
remove and separate out the following materials, then send them to
the appropriate collection centres in accordance with the environmental
hygiene regulations currently in force:
• Brushes
• Felt
• Electric and electronic parts*
• Batteries
•
Plastic parts (tanks and handlebars)
•
Metal parts (levers and frame)
(*) In particular, contact your distributor when scrapping electric and
electronic parts.
CHOOSING AND USING THE BRUSHES
POLYPROPYLENE BRUSH (PPL)
Used on all types of floors. Good resistance to wear and tear, and hot water (no greater than 50°C.).
The polypropylene is non-hygroscopic and therefore retains its characteristics even when working in
wet conditions.
ABRASIVE BRUSH
The bristles of this type of brush are charged with highly aggressive abrasives. It is used to clean very
dirty floors. To avoid floor damage, work only with the pressure strictly necessary.
BRISTLE THICKNESS
Thicker bristles are more rigid and are therefore used on smooth floors or floors with small joints.
On uneven floors or those with deep joints, it is advisable to use softer bristles which can enter the gaps
more easily.
Remember that when the bristles are worn and therefore too short, they will become rigid and are no
longer able to penetrate and clean deep down. In this case, like with over-large bristles, the brush tends
to jump.
PAD HOLDER
The pad holder is recommended for cleaning shiny surfaces.
There are two types of pad holder:
1. The traditional pad holder is fitted with a series of anchor points that allow the abrasive floor pad to be
held and dragged while working.
2. the CENTRE LOCK type pad holder not only has anchor points, but also a snap-type central locking
system in plastic that allows the abrasive floor pad to be perfectly centred and held without any risk of it
becoming detached. This type of pad holder is recommended above all for machines with more than one
brush, where the centring of the abrasive discs is difficult.
The undersigned manufacturer:
COMAC S.p.A.
Via Maestri del Lavoro, 13
37059 Santa Maria di Zevio (VR)
declares under its sole responsibility that the products
FLOOR SCRUBBING MACHINE mod. C130 BF 2015
comply with the provisions of Directives:
•
2006/42/EC: Machinery Directive.
•
2014/30/EC: Electromagnetic compatibility directive.
They also comply with the following standards:
•
EN 60335-1: Household and similar electrical appliances - Safety. Part 1: Generic standards.
•
EN 60335-2-72: Household and similar electrical appliances. Part 2: Specific standards for automatic
machines for floor treatment for commercial and industrial use.
•
EN 12100-1: Safety of Machinery - Basic concepts, general principles for design - Part 1: Basic
terminology and methodology.
•
EN 12100-2: Safety of Machinery - Basic concepts, general principles for design - Part 2: Technical
principles.
•
EN 61000-6-2: Electromagnetic compatibility (EMC) - Part 6-2: Generic standards – Immunity for
industrial environments.
•
EN 61000-6-3: Electromagnetic compatibility (EMC) - Part 6-3: Generic standards — Standard
emission for residential, commercial and light-industrial environments.
•
EN 62233: Household and similar electrical appliances - Electromagnetic fields - Methods for
evaluation and measurement.
The person authorized to compile the technical file:
Mr. Giancarlo Ruffo
Via Maestri del Lavoro, 13
37059 Santa Maria di Zevio (VR) - ITALY
Santa Maria di Zevio (VR), 11/01/2016
Comac S.p.A.
Legal representative
Giancarlo Ruffo
EC DECLARATION OF CONFORMITY
40
8
7
8
8
7
9
9
10
1
2
A
C
1
3
2
5
3
7
6
5
4
8
6
7
CODE
NO. OF
BRUSH-
ES
TYPE OF
BRISTLES
Ø
BRIS-
TLES
Ø
BRUSH-
ES
BRUSH
LENGTH
N.B.
404638
4
PPL
1.4
345
-
WHITE DISC BRUSH
404639
4
ABRASIVE
1.5
345
-
DISC BRUSH
405521
4
-
-
345
-
PAD HOLDER WITH
CENTRE LOCK
404640
1
PPL
0.7
300
1110
WHITE CYLINDRICAL
BRUSH
404642
1
ABRASIVE
0.6
300
1110
CYLINDRICAL BRUSH