Comfort Glow HFVMR18 Скачать руководство пользователя страница 9

901915-01B

For more information, visit www.desatech.com

For more information, visit www.desatech.com

9

9

During the 2-3 hour appliance break-in period, you may detect
an odor from the appliance as the various paints and com-
pounds used in the manufacturing of this log set cure. This is a
normal and temporary situation that is not cause for alarm.
However, you may want to provide extra ventilation to the room
during this time.
To ensure proper curing of the logs:
• Ignite a 2" flame and maintain it for 1 hour.
• Burn the logs in consecutive 1 hour periods raising the flame

an additional 2" to full flame height for a total of three hours.

CURING

LOGS

CLEANING AND
MAINTENANCE

• Keep the area around the log set clean and clear of debris.

• Occasionally, you may use a soft bristle brush to clean logs.

• Once every year a qualified agency or certified chimney sweep

should examine and clean the venting system of the fireplace.

OPERATING APPLIANCE

Continued

REPLACEMENT PARTS

Note:

 Use only original replacement parts. This will protect your

warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product or Parts Centrals. If they
can’t supply original replacement part(s), call DESA’s Technical
Service Department at 1-866-672-6040.

When calling DESA, have ready

• your name

• your address
• model and serial numbers of your log set
• how log set was malfunctioning
• type of gas used (propane/LP or natural gas)
• purchase date

Usually, we will ask you to return the part to the factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product or Parts Centrals. When
calling, have ready

• model number of your log set
• the replacement part number

PARTS CENTRALS

These Parts Centrals are privately-owned businesses. They have
agreed to support our customer’s needs by providing original
replacement parts and accessories.

Baltimore Electric
1348 Dixwell Avenue
Hamden, CT 06514-0322
1-800-397-7553
203-248-7553
Parts Department

Portable Heater Parts
342 N. County Rd. 400 E.
Valparaiso, IN 46383-9704
All States
219-462-7441
1-888-619-7060
Parts Department
[email protected]
[email protected]

FBD
1349 Adams St.
Bowling Green, KY 42103-3414
270-846-1199
1-800-654-8534
Fax: 1-800-846-0090
[email protected]

Master Parts Distributor
1251 Mound Ave. NW
Grand Rapids , MI 49504-2672
616-791-0505
1-800-446-1446
Fax: 1-616-791-8270
www.nbmc.com

Washer Equipment Co.
1715 Main Street
Kansas City, MO 64108-2195
KS, MO, AR
816-842-3911
www.washerparts.com

East Coast Energy Products
707 Broadway
W. Long Branch, NJ 07764-1542
732-870-8809
1-800-755-8809
www.njplaza.com/ecep

Laportes Parts and Service
2444 North 5th Street
Hartsville, SC 29550-7704
843 -332-0191
Parts Department

Cans Unlimited, Inc.
P.O. Box 645
Taylor, SC 29687-0013
All States
803-879-3009
1-800-845-5301
[email protected]

OPERATING APPLIANCE

Curing Logs

CLEANING AND MAINTENANCE

REPLACEMENT PARTS

PARTS CENTRALS

Содержание HFVMR18

Страница 1: ...oradditionalinformationcon sult a qualified installer service agency or the gas supplier WARNING This appliance is for installationonlyinasolid fuelburn ing masonry or UL127 factory built fireplace co...

Страница 2: ...use any phone in your building immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions if you cannot reach your gas supplier call the fire department 3 Never...

Страница 3: ...fts that alter burner flame patterns Ceiling fans can create drafts that alter burner flame patterns Altered burner patterns can increase sooting 9 Do not use a blower insert heat exchanger insert or...

Страница 4: ...ound windows and doors to keep the cold air out and the warm air in During heating months home owners want their homes as airtight as possible While it is good to make your home energy efficient your...

Страница 5: ...ndicated FUEL INLET PRESSURE SPECIFICATIONS W C Min Max NG 5 5 10 5 LP 11 13 Figure 2 Technical Information Charts BURNER ORIFICE LOG NATURAL PROPANE LP SIZE IN NUM IN NUM 18 111 34 073 49 24 129 30 0...

Страница 6: ...m gas meter to equipment shutoff valve see Figure 5 Apply noncorrosive leak detection fluid to gas joints Bubbles forming show a leak 4 Correct all leaks at once We recommend that you install a sedime...

Страница 7: ...nued HEARTH KIT ASSEMBLY AND INSTALLATION Kit Assembly 1 Unscrew burner inlet fitting from burner manifold 2 Place burner manifold in pan with threaded opening facing open knockout plug see Figure 6 M...

Страница 8: ...tting Off Appliance Turn gas shutoff valve clockwise to the OFF position 1 STOP Read the safety information above 2 Turn the gas shutoff valve to OFF 3 Wait five 5 minutes to clear out any gas If you...

Страница 9: ...how log set was malfunctioning type of gas used propane LP or natural gas purchase date Usually we will ask you to return the part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of...

Страница 10: ...urner orifice size Log set is smoking sooting excessively Note It is natural and unavoidable for vented gas log sets to produce moderate levels of carbon soot where flames contact the logs This is esp...

Страница 11: ...Gas leak SeeWarning statement at top of page OBSERVED PROBLEM Log Set produces a clicking ticking noise just after burner is lit or shut off Log Set produces unwanted odors Gas odor even when control...

Страница 12: ...nformation visit www desatech com For more information visit www desatech com 12 ILLUSTRATED PARTS BREAKDOWN MODELS HFVMR18 AND HFVMR24 3 6 12 10 11 10 4 7 9 5 1 8 2 ILLUSTRATED PARTS BREAKDOWN Models...

Страница 13: ...01 901066 01 Brass Air Mixer Natural Gas 1 4 901064 10 901064 03 Natural Gas Injector 1 5 901763 02 901763 01 Burner Manifold 1 6 901767 02 901767 01 Burner Pan 1 7 901242 01 901242 01 Damper Clamp S...

Страница 14: ...instructions listed under Replacement Parts on page 9 of this manual KEY PART NUMBER FOR NO 18 24 DESCRIPTION QTY 1 901656 01 901657 01 Bottom Front 1 2 2 901666 01 901667 01 Bottom Front 2 2 3 901619...

Страница 15: ...Completed College Completed Graduate School 13 Age of Purchaser Under 20 20 29 30 39 40 49 50 59 60 or Over 14 Buyer s total annual household income Under 15 000 15 000 to 19 999 20 000 to 34 999 35...

Страница 16: ...901915 01B For more information visit www desatech com For more information visit www desatech com 16 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Postage Required TAPE TAPE...

Страница 17: ...emote control operation Contains components for propane LP conversion INDIVIDUAL ROUND LOG GA9450A Not Shown Fordecorativepurposesonly Nottobeusedasadditionallogsonunit INDIVIDUAL SPLIT LOG GA9550A No...

Страница 18: ...ic cost labor transportation and any and all such other costs related to repairing a defective log set will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION...

Отзывы: