TABLE OF CONTENTS
SAFETY INFORMATION

SAFETY INFORMATION

Carbon Monoxide Poisoning:

 

Early signs of carbon monoxide

poisoning resemble the flu, with headaches, dizziness, or nausea. If
you have these signs, the log set may not be working properly. Get
fresh air at once!
 Have log set serviced. Some people are more
affected by carbon monoxide than others. These include pregnant
women, people with heart or lung disease or anemia, those under the
influence of alcohol, and those at high altitudes.

Natural Gas:

 Natural gas is odorless. An odor-making agent is

added to the gas. The odor helps you detect a gas leak. However, the
odor added to the gas can fade. Gas may be present even though no
odor exists.

Make certain you read and understand all warnings. Keep this
manual for reference. It is your guide to safe and proper operation
of this log set.

WARNING ICON

G 001

 WARNINGS

IMPORTANT: Read this owner’s manual carefully and
completely before trying to assemble, operate, or ser-
vice this log set. Improper use of this log set can cause
serious injury or death from burns, fire, explosion,
electrical shock, and carbon monoxide poisoning.

 DANGER: Carbon monoxide poisoning may lead

to death!

 WARNING: Any change to this log set or its

controls can be dangerous.

 WARNING: Keep flue open when operating unit.

1.

This appliance, as supplied, is only for use with the type of gas
indicated on the rating plate. This appliance is convertible for
use with propane/LP, using the GA9050 or GA9150 pilot kit.

2.

If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not use any phone in

your building

• immediately call your gas supplier from a neighbor’s phone.

Follow the gas supplier’s instructions

• if you cannot reach your gas supplier, call the fire department

3.

Never install the log set
• in a recreational vehicle
• where curtains, furniture, clothing, or other flammable ob-

jects are less than 42 inches from the front, top, or sides of
the log set

• in high traffic areas
• in windy or drafty areas

4.

Before installing in a solid fuel burning fireplace, the chimney
flue and firebox must be cleaned of soot, creosote, ashes, and
loose paint by a qualified chimney cleaner. Creosote will ig-
nite if highly heated. Inspect chimney flue for damage. If dam-
aged, repair flue before operating heater.

5.

You must operate this log set with a fireplace screen in place.
Make sure fireplace screen is closed before running log set. If the
fireplace has glass doors, they must remain fully OPEN while
this log set is in operation.

6.

This log set is designed to be smokeless. If logs ever appear to
smoke, turn off appliance and call a qualified service person.

Note:

 During initial operation, slight smoking could occur due

to log curing and the burning of manufacturing residues. You
may wish to add more ventilation by opening a window.

7.

To reduce the creation of soot, follow the instructions in Clean-
ing and Maintenance
, page 9.

 WARNING: This product contains and/or generates

chemicals known to the State of California to cause
cancer or birth defects, or other reproductive harm.

TABLE OF CONTENTS

SAFETY INFORMATION ............................................................ 2

UNPACKING ............................................................................... 3

PRODUCT IDENTIFICATION ..................................................... 3

LOCAL CODES ........................................................................... 3

OPTIONAL PRODUCT FEATURES ........................................... 4

AIR FOR COMBUSTION AND VENTILATION ........................... 4

INSTALLATION ........................................................................... 4

OPERATING APPLIANCE .......................................................... 8

CLEANING AND MAINTENANCE .............................................. 9

REPLACEMENT PARTS ............................................................ 9

PARTS CENTRALS .................................................................... 9

TROUBLESHOOTING .............................................................. 10

ILLUSTRATED PARTS BREAKDOWN AND PARTS LIST ....... 12

OWNER’S REGISTRATION FORM .......................................... 15

ACCESSORIES ........................................................................ 17

WARRANTY INFORMATION ...................................... Back Cover

Содержание HFVMR18

Страница 1: ...oradditionalinformationcon sult a qualified installer service agency or the gas supplier WARNING This appliance is for installationonlyinasolid fuelburn ing masonry or UL127 factory built fireplace co...

Страница 2: ...use any phone in your building immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions if you cannot reach your gas supplier call the fire department 3 Never...

Страница 3: ...fts that alter burner flame patterns Ceiling fans can create drafts that alter burner flame patterns Altered burner patterns can increase sooting 9 Do not use a blower insert heat exchanger insert or...

Страница 4: ...ound windows and doors to keep the cold air out and the warm air in During heating months home owners want their homes as airtight as possible While it is good to make your home energy efficient your...

Страница 5: ...ndicated FUEL INLET PRESSURE SPECIFICATIONS W C Min Max NG 5 5 10 5 LP 11 13 Figure 2 Technical Information Charts BURNER ORIFICE LOG NATURAL PROPANE LP SIZE IN NUM IN NUM 18 111 34 073 49 24 129 30 0...

Страница 6: ...m gas meter to equipment shutoff valve see Figure 5 Apply noncorrosive leak detection fluid to gas joints Bubbles forming show a leak 4 Correct all leaks at once We recommend that you install a sedime...

Страница 7: ...nued HEARTH KIT ASSEMBLY AND INSTALLATION Kit Assembly 1 Unscrew burner inlet fitting from burner manifold 2 Place burner manifold in pan with threaded opening facing open knockout plug see Figure 6 M...

Страница 8: ...tting Off Appliance Turn gas shutoff valve clockwise to the OFF position 1 STOP Read the safety information above 2 Turn the gas shutoff valve to OFF 3 Wait five 5 minutes to clear out any gas If you...

Страница 9: ...how log set was malfunctioning type of gas used propane LP or natural gas purchase date Usually we will ask you to return the part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of...

Страница 10: ...urner orifice size Log set is smoking sooting excessively Note It is natural and unavoidable for vented gas log sets to produce moderate levels of carbon soot where flames contact the logs This is esp...

Страница 11: ...Gas leak SeeWarning statement at top of page OBSERVED PROBLEM Log Set produces a clicking ticking noise just after burner is lit or shut off Log Set produces unwanted odors Gas odor even when control...

Страница 12: ...nformation visit www desatech com For more information visit www desatech com 12 ILLUSTRATED PARTS BREAKDOWN MODELS HFVMR18 AND HFVMR24 3 6 12 10 11 10 4 7 9 5 1 8 2 ILLUSTRATED PARTS BREAKDOWN Models...

Страница 13: ...01 901066 01 Brass Air Mixer Natural Gas 1 4 901064 10 901064 03 Natural Gas Injector 1 5 901763 02 901763 01 Burner Manifold 1 6 901767 02 901767 01 Burner Pan 1 7 901242 01 901242 01 Damper Clamp S...

Страница 14: ...instructions listed under Replacement Parts on page 9 of this manual KEY PART NUMBER FOR NO 18 24 DESCRIPTION QTY 1 901656 01 901657 01 Bottom Front 1 2 2 901666 01 901667 01 Bottom Front 2 2 3 901619...

Страница 15: ...Completed College Completed Graduate School 13 Age of Purchaser Under 20 20 29 30 39 40 49 50 59 60 or Over 14 Buyer s total annual household income Under 15 000 15 000 to 19 999 20 000 to 34 999 35...

Страница 16: ...901915 01B For more information visit www desatech com For more information visit www desatech com 16 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Postage Required TAPE TAPE...

Страница 17: ...emote control operation Contains components for propane LP conversion INDIVIDUAL ROUND LOG GA9450A Not Shown Fordecorativepurposesonly Nottobeusedasadditionallogsonunit INDIVIDUAL SPLIT LOG GA9550A No...

Страница 18: ...ic cost labor transportation and any and all such other costs related to repairing a defective log set will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION...

Отзывы: