Comfort Glow HFVMR18 Скачать руководство пользователя страница 4

901915-01B

For more information, visit www.desatech.com

For more information, visit www.desatech.com

4

INSTALLATION

 WARNING: Before installing in a solid fuel burning

fireplace, the chimney flue and firebox must be cleaned
of soot, creosote, ashes, and loose paint by a qualified
chimney cleaner. Creosote will ignite if highly heated.
A dirty chimney flue may create and distribute soot
within the house. Inspect chimney flue for damage. If
damaged, repair flue before operating heater.

NOTICE: Installation, service, and repair of this appli-
ance must be performed by a qualified installer,
service agency, company or gas supplier experi-
enced with this type of gas appliance. Only factory
authorized components listed in these instructions
may be used in accordance with the manufacturer’s
instructions and all codes and requirements of the
authority having jurisdiction. Any modifications to
this kit, or use of unauthorized components or acces-
sory items will void the manufacturer’s warranty, and
may result in a hazardous condition.

 CAUTION: Do not remove the data plates attached

to the burner pan. The data plates contain important
warranty and safety information.

FLUE OPENING SPECIFICATIONS

Note:

 This vented appliance must be installed only in a solid-fuel

burning fireplace with a working flue and constructed of noncom-
bustible material.

The charts in Figure 2, page 5 indicate technical information
regarding the installation of your gas log set. Please make sure that
all of the specifications shown are applicable before installation is
attempted.

The fireplace must include a working flue and venting system with
the minimum openings shown in the Figure 2, page 5.

Today’s homes are built more energy efficient than ever. New
materials, increased insulation, and new construction methods help
reduce heat loss in homes. Home owners weather strip and caulk
around windows and doors to keep the cold air out and the warm air
in. During heating months, home owners want their homes as airtight
as possible.

While it is good to make your home energy efficient, your home
needs to breathe. Fresh air must enter your home. All fuel-burning
appliances need fresh air for proper combustion and ventilation.

Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances
draw air from the house to operate. You must provide adequate fresh
air for these appliances. This will insure proper venting of vented
fuel-burning appliances.

AIR FOR COMBUSTION AND
VENTILATION

 WARNING: This appliance shall not be installed in

a confined space or unusually tight construction
unless provisions are provided for adequate com-
bustion and ventilation air. Read the following in-
structions to insure proper fresh air for this and other
fuel-burning appliances in your home.

OPTIONAL PRODUCT
FEATURES

ON/OFF SAFETY VALVE/PILOT KIT AND
PROPANE/LP CONVERSION

An optional valve/safety pilot kit with a piezo ignitor is available for
this appliance. This system requires no matches, batteries, or other
sources to light. You must use this optional system for LP conver-
sion. See Accessories, page 17.

REMOTE CONTROL READY (MILLIVOLT)
SAFETY VALVE/PILOT KIT

An optional millivolt valve/safety pilot kit with a piezo ignitor is
available for this appliance. This system requires no matches,
batteries, or other sources to light. This system may be connected to
a wall switch or hand-held wireless remote control. See Accesso-
ries
, page 17.

REMOTE CONTROL ACCESSORIES

There is an optional hand-held ON/OFF remote control that can be
purchased separately for this log set. You must use the millivolt
valve/safety pilot kit to use remote accessories with this appliance.
See Accessories, page 17.

A wall switch is also available for this appliance. You must use the
millivolt valve/safety pilot kit to use the wall switch with this
appliance. See Accessories, page 17.

OPTIONAL PRODUCT FEATURES
AIR FOR COMBUSTION AND VENTILATION
INSTALLATION

Flue Opening Specifications

Содержание HFVMR18

Страница 1: ...oradditionalinformationcon sult a qualified installer service agency or the gas supplier WARNING This appliance is for installationonlyinasolid fuelburn ing masonry or UL127 factory built fireplace co...

Страница 2: ...use any phone in your building immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions if you cannot reach your gas supplier call the fire department 3 Never...

Страница 3: ...fts that alter burner flame patterns Ceiling fans can create drafts that alter burner flame patterns Altered burner patterns can increase sooting 9 Do not use a blower insert heat exchanger insert or...

Страница 4: ...ound windows and doors to keep the cold air out and the warm air in During heating months home owners want their homes as airtight as possible While it is good to make your home energy efficient your...

Страница 5: ...ndicated FUEL INLET PRESSURE SPECIFICATIONS W C Min Max NG 5 5 10 5 LP 11 13 Figure 2 Technical Information Charts BURNER ORIFICE LOG NATURAL PROPANE LP SIZE IN NUM IN NUM 18 111 34 073 49 24 129 30 0...

Страница 6: ...m gas meter to equipment shutoff valve see Figure 5 Apply noncorrosive leak detection fluid to gas joints Bubbles forming show a leak 4 Correct all leaks at once We recommend that you install a sedime...

Страница 7: ...nued HEARTH KIT ASSEMBLY AND INSTALLATION Kit Assembly 1 Unscrew burner inlet fitting from burner manifold 2 Place burner manifold in pan with threaded opening facing open knockout plug see Figure 6 M...

Страница 8: ...tting Off Appliance Turn gas shutoff valve clockwise to the OFF position 1 STOP Read the safety information above 2 Turn the gas shutoff valve to OFF 3 Wait five 5 minutes to clear out any gas If you...

Страница 9: ...how log set was malfunctioning type of gas used propane LP or natural gas purchase date Usually we will ask you to return the part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of...

Страница 10: ...urner orifice size Log set is smoking sooting excessively Note It is natural and unavoidable for vented gas log sets to produce moderate levels of carbon soot where flames contact the logs This is esp...

Страница 11: ...Gas leak SeeWarning statement at top of page OBSERVED PROBLEM Log Set produces a clicking ticking noise just after burner is lit or shut off Log Set produces unwanted odors Gas odor even when control...

Страница 12: ...nformation visit www desatech com For more information visit www desatech com 12 ILLUSTRATED PARTS BREAKDOWN MODELS HFVMR18 AND HFVMR24 3 6 12 10 11 10 4 7 9 5 1 8 2 ILLUSTRATED PARTS BREAKDOWN Models...

Страница 13: ...01 901066 01 Brass Air Mixer Natural Gas 1 4 901064 10 901064 03 Natural Gas Injector 1 5 901763 02 901763 01 Burner Manifold 1 6 901767 02 901767 01 Burner Pan 1 7 901242 01 901242 01 Damper Clamp S...

Страница 14: ...instructions listed under Replacement Parts on page 9 of this manual KEY PART NUMBER FOR NO 18 24 DESCRIPTION QTY 1 901656 01 901657 01 Bottom Front 1 2 2 901666 01 901667 01 Bottom Front 2 2 3 901619...

Страница 15: ...Completed College Completed Graduate School 13 Age of Purchaser Under 20 20 29 30 39 40 49 50 59 60 or Over 14 Buyer s total annual household income Under 15 000 15 000 to 19 999 20 000 to 34 999 35...

Страница 16: ...901915 01B For more information visit www desatech com For more information visit www desatech com 16 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Postage Required TAPE TAPE...

Страница 17: ...emote control operation Contains components for propane LP conversion INDIVIDUAL ROUND LOG GA9450A Not Shown Fordecorativepurposesonly Nottobeusedasadditionallogsonunit INDIVIDUAL SPLIT LOG GA9550A No...

Страница 18: ...ic cost labor transportation and any and all such other costs related to repairing a defective log set will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION...

Отзывы: