Comfort Glow HFVMR18 Скачать руководство пользователя страница 5

901915-01B

For more information, visit www.desatech.com

For more information, visit www.desatech.com

5

5

CHECK GAS TYPE

Use only natural gas. If your gas supply is not natural gas, you must
install ON/OFF Safety Valve/Pilot Kit (see Accessories, page 17).
Call dealer where you bought log set.

If the fireplace does not have a gas supply shut-off valve, one must
be installed.

VENTING SPECIFICATIONS FOR
INSTALLATION

The fireplace chimney flue and vent must be drafting properly. To
check the vent for proper drafting: Light a tightly rolled newspaper
on one end and place it at the inside front edge of the fireplace.
Observe the smoke and be sure the vent is properly drawing it up the
chimney. If the smoke spills out into the room, extinguish the flame
and remove any obstruction until proper venting is achieved.

The chimney flue must remain open a minimum of 3" at all times
during the operation of this log set.

MODEL

DESCRIPTION

HFVMR18

18" Multi-Side

55,000

45,000

8" dia.

HFVMR24

24" Multi-Side

65,000

55,000

8" dia.

Btu Input

Natural

Gas

Btu Input

Propane/LP

Gas

Minimum

Vent

Opening

         MINIMUM FIREBOX SIZES

LOG

FRONT

BACK

SIZE WIDTH* WIDTH**

DEPTH HEIGHT

18"

28"

28"

16"

18"

24"

29 

3

/

4

"

29 

3

/

4

"

16"

18"

* Add 6" if safety valve/pilot is used
**At depth indicated

FUEL INLET PRESSURE
SPECIFICATIONS (W.C.)

Min.

Max.

NG

5.5"

10.5"

LP

11"

13"

Figure 2 - Technical Information Charts

BURNER ORIFICE

LOG

NATURAL

PROPANE/LP

SIZE

IN.

NUM.

IN.

NUM.

18"

.111

34

.073

49

24"

.129

30

.086

 44

INSTALLATION

Continued

INSTALLING DAMPER CLAMP

Secure the damper stop clamp provided to the leading edge of the
damper as shown in Figure 3. If for any reason this clamp doesn't
work on your fireplace, another suitable clamp or permanent stop
must be installed, or the damper blade must be cut or removed.

Manufactured Fireplace

Masonry Fireplace

Damper Clamp

Damper

Damper

Damper Clamp

Damper

Figure 3 - Attaching Damper Clamp

CONNECTING TO GAS SUPPLY

 WARNING: A qualified service person must con-

nect log set to gas supply. Follow all local codes.

Installation Items Needed

Before installing log set, make sure you have the items listed below.

• piping (check local codes)

• sealant (resistant to propane/LP gas)

• equipment shutoff valve

• test gauge connection

• adjustable (crescent) wrench or pliers

• sediment trap

• tee joint

• pipe wrench

 CAUTION: Use only new, black iron or steel pipe.

Internally-tinned copper tubing may be used in certain
areas. Check your local codes. Use pipe of 1/2" diam-
eter or greater to allow proper gas volume to log set. If
pipe is too small, undue loss of volume will occur.

INSTALLATION

Flue Opening Specifications (Cont.)

Check Gas Type

Venting Specifications for Installation

Installing Damper Clamp

Connecting To Gas Supply

Содержание HFVMR18

Страница 1: ...oradditionalinformationcon sult a qualified installer service agency or the gas supplier WARNING This appliance is for installationonlyinasolid fuelburn ing masonry or UL127 factory built fireplace co...

Страница 2: ...use any phone in your building immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions if you cannot reach your gas supplier call the fire department 3 Never...

Страница 3: ...fts that alter burner flame patterns Ceiling fans can create drafts that alter burner flame patterns Altered burner patterns can increase sooting 9 Do not use a blower insert heat exchanger insert or...

Страница 4: ...ound windows and doors to keep the cold air out and the warm air in During heating months home owners want their homes as airtight as possible While it is good to make your home energy efficient your...

Страница 5: ...ndicated FUEL INLET PRESSURE SPECIFICATIONS W C Min Max NG 5 5 10 5 LP 11 13 Figure 2 Technical Information Charts BURNER ORIFICE LOG NATURAL PROPANE LP SIZE IN NUM IN NUM 18 111 34 073 49 24 129 30 0...

Страница 6: ...m gas meter to equipment shutoff valve see Figure 5 Apply noncorrosive leak detection fluid to gas joints Bubbles forming show a leak 4 Correct all leaks at once We recommend that you install a sedime...

Страница 7: ...nued HEARTH KIT ASSEMBLY AND INSTALLATION Kit Assembly 1 Unscrew burner inlet fitting from burner manifold 2 Place burner manifold in pan with threaded opening facing open knockout plug see Figure 6 M...

Страница 8: ...tting Off Appliance Turn gas shutoff valve clockwise to the OFF position 1 STOP Read the safety information above 2 Turn the gas shutoff valve to OFF 3 Wait five 5 minutes to clear out any gas If you...

Страница 9: ...how log set was malfunctioning type of gas used propane LP or natural gas purchase date Usually we will ask you to return the part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of...

Страница 10: ...urner orifice size Log set is smoking sooting excessively Note It is natural and unavoidable for vented gas log sets to produce moderate levels of carbon soot where flames contact the logs This is esp...

Страница 11: ...Gas leak SeeWarning statement at top of page OBSERVED PROBLEM Log Set produces a clicking ticking noise just after burner is lit or shut off Log Set produces unwanted odors Gas odor even when control...

Страница 12: ...nformation visit www desatech com For more information visit www desatech com 12 ILLUSTRATED PARTS BREAKDOWN MODELS HFVMR18 AND HFVMR24 3 6 12 10 11 10 4 7 9 5 1 8 2 ILLUSTRATED PARTS BREAKDOWN Models...

Страница 13: ...01 901066 01 Brass Air Mixer Natural Gas 1 4 901064 10 901064 03 Natural Gas Injector 1 5 901763 02 901763 01 Burner Manifold 1 6 901767 02 901767 01 Burner Pan 1 7 901242 01 901242 01 Damper Clamp S...

Страница 14: ...instructions listed under Replacement Parts on page 9 of this manual KEY PART NUMBER FOR NO 18 24 DESCRIPTION QTY 1 901656 01 901657 01 Bottom Front 1 2 2 901666 01 901667 01 Bottom Front 2 2 3 901619...

Страница 15: ...Completed College Completed Graduate School 13 Age of Purchaser Under 20 20 29 30 39 40 49 50 59 60 or Over 14 Buyer s total annual household income Under 15 000 15 000 to 19 999 20 000 to 34 999 35...

Страница 16: ...901915 01B For more information visit www desatech com For more information visit www desatech com 16 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Postage Required TAPE TAPE...

Страница 17: ...emote control operation Contains components for propane LP conversion INDIVIDUAL ROUND LOG GA9450A Not Shown Fordecorativepurposesonly Nottobeusedasadditionallogsonunit INDIVIDUAL SPLIT LOG GA9550A No...

Страница 18: ...ic cost labor transportation and any and all such other costs related to repairing a defective log set will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION...

Отзывы: