9
3
Temperature Measurement
Configuration
3.1 Temperature Measurement Requirements
• Thermal camera is temperature-sensitive. When it is used for temperature
measuring, in order to ensure the accuracy, the recommended ambient
temperature is 10~35
℃
, and the infrared light should be turned off during the
temperature measurement.
• Thermal camera can be adopted independently, but together with blackbody the
accuracy will be better.
• Thermal camera should be used in a stable indoor environment without wind.
Please make sure the monitoring field is far away from any objects that could
produce airflow, high temperature, reflection.
• Don’t install the thermal camera opposite to a door, air conditioner or any place in
sunshine.
• It is recommended to use 12VDC power supply at high temperature to reduce
power consumption.
• For aisle monitoring, the best temperature measurement distance is 2~4m,
recommended distance should be 2~6m.
• Set up a one-way temperature measuring zone and make sure the camera can
clearly see the human face.
• After turning on, the thermal camera needs to wait 20~30 minutes to be steady.