The Comco Warranty
Comco warrants that the AccuFlo® model AF10‐E will be free from all defects in material and workmanship
under normal use for a period of one year from the date of purchase or 2,000 hours of normal operation,
whichever comes first.
The warranty period begins when the equipment ships from the Comco facility and applies to the original
owner only. Comco is not liable for damages from any cause or use of such equipment beyond the cost of
repairing any defective parts.
If the equipment fails to perform satisfactorily during the warranty period, Comco has the option to do any
one of the following: 1) Send replacement parts to the customer to be installed by the customer; 2) Repair
the unit at the customer’s facility; or 3) Request that the unit be returned to the Comco factory. Any
replacement parts shall be furnished by Comco without cost, F.O.B. the Comco factory in Burbank, California,
provided that Comco is notified of the defect within the warranty period. Any defective parts shall be
returned to Comco for inspection and analysis.
Exclusions
The above warranty does not apply to defects or problems resulting from improper or inadequate
maintenance by the customer; unauthorized modification or misuse; failure to follow the operating
instructions; the use of any supplies or parts, including but not limited to nozzles, powders, and attachments,
not manufactured or supplied by Comco.
The warranty also does not cover problems resulting from improper or inadequate facilities (contaminated
air; improper power) or items that should be expected to wear in normal operation, such as nozzles,
abrasives, tubing or fittings.
This is Comco’s only warranty and is in lieu of all other warranties of merchantability and fitness for any
particular purpose. No representations or warranties are authorized except as herein stated.
Always operate the AccuFlo® blaster in an appropriate
workstation with dust collection.
Never blast toward someone’s face or eyes. This is a
pressure device.
The Lexan window on the tank cover is abrasion
resistant. However, contact with certain chemicals can
weaken the cover and cause it to crack.
Inspect the cover daily and replace immediately if
cracks develop.
Refer to Comco Technical Support for full details.
13
Tech Support: 1‐818‐841‐5500
WARNING
MAXIMUM BLAST SETTING ON YOUR BLASTER
Never operate any micro‐abrasive blaster with
the air pressure regulator fully open. Check your
compressor settings to determine the air pressure
level it uses to trigger the re‐pressurize cycle. The
blast pressure setting on your blaster should
always be set at 10 psi below this point, which is
the lowest supply pressure coming from your
compressor. If the inlet pressure drops below the
blast pressure setting, air and abrasive will flow
backward through your system and damage
critical components.