9
Tech Support: 1‐818‐841‐5500
Maintenance Counters
AccuFlo® Modulator
For easier maintenance there are two counters on
the front panel.
The
CYC
counts the number of blast cycles on the
AccuFlo (each time the PowderGate® valve opens.)
Abrasive type and blast pressure will impact
maintenance frequency, but typical configurations
will last more than 250,000 cycles before needing
maintenance.
The
HRS
counter records the number of blast hours
(i.e. actual time the modulator has operated.)
Your maintenance requirements may vary with your
application.
The modulator should be replaced after 5000 hours
of operation.
To replace the AccuFlo® AF10‐E modulator:
•
Disconnect 3 colored tubes from the modulator
and the electrical plug from front panel.
•
Remove the two screws holding the modulator
to the bracket using a Phillips screwdriver.
•
Install the new modulator in reverse order,
making sure the two grommets remain in the
bracket.
MODULATOR
MB2250‐1 (115V)
MB2250‐2 (230V)