background image

17 

 

www.combisteel.com 

 

Appendix D 

 

INSTRUCTION 

EKC202B, EKC302B CONTROLLER SETTINGS ADJUSTMENT 

 
1. 

PURPOSE 

The  controller  as  part  of  the  refrigeration  equipment  is  designed  to  control  its  operation  and  provides  the 
following: 

 

maintaining the temperature in the refrigerated space within the required range; 

 

automatic defrost of the air cooler; 

 

compressor protection. 

 
The front panel of the controller is shown in Fig. 1. 
 

 

Fig. 1. 
1, 2, 3 - programming keys; 4 - display; 5 "minus" signal; 6 air cooler fan activation indicator (illuminated);  
7 defrosting indicator (illuminated); 8 - refrigeration indicator (illuminated). 
 
 
2. 

BRIEF DESCRIPTION 

The front panel of the controller contains three programming keys (1), (2), (3) and a display that shows three 
numbers  or  letters  (4),  a  minus  sign  (5),  an  air  cooler  fan  activation  signal  (6),  a  defrosting  signal  (7),  and  a 
refrigeration signal (8). 
The controller maintains the interior temperature by periodical starting and stopping the compressor according 
to a signal received from the sensor installed in the air cooler. If the interior temperature exceeds the set value 
(the  first  line  in  Table  1),  then  the  controller  activates  the  compressor.  After  reaching  the  specified  interior 
temperature, the controller stops the compressor. When the compressor is disabled, the interior temperature 
increases due to heat flows, and when a value equal to the sum of the previous set value (the first line in Table 
1) and the value "r01" is reached, the controller activates the com-pressor. 
When products are cooled (the compressor is running), the display (4) shows the interior temperature value and 
the refrigeration signal (8). When the compressor is disabled, the refrigeration signal (8) is not displayed. 
To see the temperature on S5 evaporator sensor, press briefly the key (2), and to activate the forced defrosting, 
press and hold the key (2) for 5 seconds. 
 
3. 

TEMPERATURE SETTING ADJUSTMENT 

Set value adjustment procedure: 

 

press the key (3) until the temperature set value appears on the display; 

 

select the desired value by pressing the keys (1) or (2) ; 

 

press the key (3) to record the value. 

 
 

 

Содержание 7469.0100

Страница 1: ...Wall Mounted Unit Max 7469 0100 7469 0105 7469 0110 User Manual Gebruikershandleiding Gebrauchsanweisung Le mode d emploi...

Страница 2: ...fications 7 2 1 Scope of delivery 7 2 2 Acceptance certificate 7 3 Proper use 7 3 1 General guidelines 7 3 2 Safety measures 7 3 3 Display case installation 8 3 4 Pre starting procedure of display cas...

Страница 3: ...maximum relative humidity 80 22 C maximum relative humidity 65 25 C maximum relative humidity 60 The temperature range in the useful volume for the display cases without front glazing open is 1 to 7...

Страница 4: ...1 7 0 66 0 27 1955 1075 2040 510 nte L 2500 8 0 4 0 3 25 3 5 2 2 0 86 0 34 2580 1075 2040 610 nte L 3750 12 0 6 0 4 9 5 0 3 1 1 27 0 48 3830 1075 2040 900 nte L FV 1250 3 3 2 0 1 65 1 9 1 2 0 45 0 19...

Страница 5: ...g 2 Rear moulded wall 3 Upper moulded wall top 4 Side moulded or double glazed wall end wall 5 Height adjustable support feet 6 Load bearing posts with perforated panels 7 Shelves with guides and stop...

Страница 6: ...rosting time and frequency are determined by the controller settings The control panel consists of 1 Electronic controller 2 Illuminated key switch Figure 3 Control panel The electronic controller 1 i...

Страница 7: ...of the display cases during their intended use The display case service life and safety in operation depend on observance of the operating rules 3 2 Safety measures The display cases meet the safety...

Страница 8: ...ry package Remove the display case from the wooden pallet by unscrewing the fixing bolts Indoors the product can only be moved in accordance with the handling circuit on the nameplate Tilt the display...

Страница 9: ...ly after the set temperature is reached in the display case interior DO NOT exceed the load limits Warning Products and semi finished products should be pre cooled Products and semi finished products...

Страница 10: ...not installed correctly The refrigeration unit pipelines are in contact with the housing or with each other Adjust the display case installation level using the feet Check the pipeline attachment War...

Страница 11: ...e Centers 5 Storage The display cases should be stored factory packaged not stacked under the conditions of exposure to climatic factors of group 3 acc to GOST 15150 and a temperature of not lower tha...

Страница 12: ...personal protective equipment Shut down the display cases and disconnect the electrical lines before disposal The process liquid oil refrigerant should be removed from the refrigeration system and re...

Страница 13: ...___________________________________________________________________ name of organization ___________________________________________________________________ full name certificate for installation and...

Страница 14: ...lights MVE1 MVE6 Air cooler fans A1 Controller ES Evaporator heating elements Sair S5 NTC temperature sensors YA Timer relay coil Option Display case length mm Number of fans Number of lamps Number o...

Страница 15: ...15 www combisteel com Appendix C normative Refrigerating unit and melt water drain pipeline connection diagram...

Страница 16: ...16 www combisteel com...

Страница 17: ...the compressor according to a signal received from the sensor installed in the air cooler If the interior temperature exceeds the set value the first line in Table 1 then the controller activates the...

Страница 18: ...unit F F r09 Correction of the signal from thermostat sensor 10 10 0 K r12 Manual service 1 stop regulation 0 start regulation 1 1 r13 Displacement of reference during night operation 10 10 0 K r39 Ac...

Страница 19: ...ed sensor type t ntc 5 kOhm ntc 15 Display step 0 5 normal 0 1 at Pt sensor no yes no 16 Maximum hold time after coordinated defrost 20 o46 Cleaning 0 o64 Access code 2 partly access 0 100 0 67 Replac...

Страница 20: ...20 www combisteel com Appendix E Night cover installation instructions Step 1 Step 2 Step 3...

Страница 21: ...21 www combisteel com Step 4 Step 5...