background image

12 

 

www.combisteel.com 

 

8 Disposal  

Display cases that have reached the end of their service life should be disposed. Display cases should be disposed 
by  appropriately  qualified  personnel  authorized  for  these  works  and  instructed  on  safe  work  practices  and 
procedures.  
The  personnel  disposing  the  display  cases  should  wear  protective  clothing  and  use  personal  protective 
equipment. Shut down the display cases and disconnect the electrical lines before disposal.  
The process liquid (oil, refrigerant) should be removed from the refrigeration system and recycled, regenerated 
or disposed by specialized organizations.  
The  fire  safety,  electrical  safety,  environmental  safety  and  handling  safety  requirements  shall  be  met  during 
disassembly.  
Before disposal of the display case, disassemble and sort its components according to the materials from which 
they are made. Metal structures are subject to scrapping. 
 
 

 

Содержание 7469.0100

Страница 1: ...Wall Mounted Unit Max 7469 0100 7469 0105 7469 0110 User Manual Gebruikershandleiding Gebrauchsanweisung Le mode d emploi...

Страница 2: ...fications 7 2 1 Scope of delivery 7 2 2 Acceptance certificate 7 3 Proper use 7 3 1 General guidelines 7 3 2 Safety measures 7 3 3 Display case installation 8 3 4 Pre starting procedure of display cas...

Страница 3: ...maximum relative humidity 80 22 C maximum relative humidity 65 25 C maximum relative humidity 60 The temperature range in the useful volume for the display cases without front glazing open is 1 to 7...

Страница 4: ...1 7 0 66 0 27 1955 1075 2040 510 nte L 2500 8 0 4 0 3 25 3 5 2 2 0 86 0 34 2580 1075 2040 610 nte L 3750 12 0 6 0 4 9 5 0 3 1 1 27 0 48 3830 1075 2040 900 nte L FV 1250 3 3 2 0 1 65 1 9 1 2 0 45 0 19...

Страница 5: ...g 2 Rear moulded wall 3 Upper moulded wall top 4 Side moulded or double glazed wall end wall 5 Height adjustable support feet 6 Load bearing posts with perforated panels 7 Shelves with guides and stop...

Страница 6: ...rosting time and frequency are determined by the controller settings The control panel consists of 1 Electronic controller 2 Illuminated key switch Figure 3 Control panel The electronic controller 1 i...

Страница 7: ...of the display cases during their intended use The display case service life and safety in operation depend on observance of the operating rules 3 2 Safety measures The display cases meet the safety...

Страница 8: ...ry package Remove the display case from the wooden pallet by unscrewing the fixing bolts Indoors the product can only be moved in accordance with the handling circuit on the nameplate Tilt the display...

Страница 9: ...ly after the set temperature is reached in the display case interior DO NOT exceed the load limits Warning Products and semi finished products should be pre cooled Products and semi finished products...

Страница 10: ...not installed correctly The refrigeration unit pipelines are in contact with the housing or with each other Adjust the display case installation level using the feet Check the pipeline attachment War...

Страница 11: ...e Centers 5 Storage The display cases should be stored factory packaged not stacked under the conditions of exposure to climatic factors of group 3 acc to GOST 15150 and a temperature of not lower tha...

Страница 12: ...personal protective equipment Shut down the display cases and disconnect the electrical lines before disposal The process liquid oil refrigerant should be removed from the refrigeration system and re...

Страница 13: ...___________________________________________________________________ name of organization ___________________________________________________________________ full name certificate for installation and...

Страница 14: ...lights MVE1 MVE6 Air cooler fans A1 Controller ES Evaporator heating elements Sair S5 NTC temperature sensors YA Timer relay coil Option Display case length mm Number of fans Number of lamps Number o...

Страница 15: ...15 www combisteel com Appendix C normative Refrigerating unit and melt water drain pipeline connection diagram...

Страница 16: ...16 www combisteel com...

Страница 17: ...the compressor according to a signal received from the sensor installed in the air cooler If the interior temperature exceeds the set value the first line in Table 1 then the controller activates the...

Страница 18: ...unit F F r09 Correction of the signal from thermostat sensor 10 10 0 K r12 Manual service 1 stop regulation 0 start regulation 1 1 r13 Displacement of reference during night operation 10 10 0 K r39 Ac...

Страница 19: ...ed sensor type t ntc 5 kOhm ntc 15 Display step 0 5 normal 0 1 at Pt sensor no yes no 16 Maximum hold time after coordinated defrost 20 o46 Cleaning 0 o64 Access code 2 partly access 0 100 0 67 Replac...