Fig. 4. Power connection diagram 
QF, QF1 – automatic circuit breakers; 

     

 

 

 

 

          

XP – 3 pole plug and socket EURO connector with grounding terminal. 
 
For the wiring diagram see Appendix B. 

 Warning: Do not operate equipment with a missing or faulty ground connection.   

  Warning:  Before  dismantling  and  depressurization  of  refrigeration  system  components,  drain  the 

refrigerant into a special container, avoiding its leakage into the atmosphere. 
Precaution: The display cases are not intended for use by persons (including children) with reduced physical or 
mental capabilities, or lack of experience or knowledge, unless they are supervised or instructed regarding the 
product use by a person responsible for their safety. Children should be supervised to prevent playing with the 
product. In case of non-compliance with these safety  measures, the manufacturer  shall not  be liable for the 
safety. 
 

3.3 Display case installation.  

Warning: When the display case is delivered, check the packaging for damages. If there are any defects, 

make a claim to the transport company. The display cases should be transported in a vertical position only. 
 
Carefully unpack the display case, taking all necessary precautions to avoid mechanical damage to the external 
front surfaces of the product. Remove the components from the interior. Read the datasheet. Check the delivery 
package. 
Remove the display case from the wooden pallet by unscrewing the fixing bolts. 
Indoors, the product can only be moved in accordance with the handling circuit on the nameplate. 
Tilt the display case 15° back and screw the front feet, then tilt it forward and screw the rear feet.  
Set the display case level to a stable horizontal position using height-adjustable feet. 
When installing display cases at the operating site, observe the following conditions: 

-

 

the ambient air temperature should not exceed 25°C, because at temperatures above 25°C and relative 
humidity of more than 60%, the technical characteristics specified in p. 1.1 are not guaranteed; 

-

 

provide an air conditioning system in the room to maintain normal operating conditions, because the 
common  ventilation  will  increase  the  humidity,  which  will  reduce  the  operational  reliability; 
- do not install showcases near doors or in halls with artificial air flows to avoid air flows of more than 
0.2 m/sec, humidifying the air; 

-

 

install the display case at least 1 m away from the heat source, and sun-warmed walls and ceilings; 

-

 

keep the clearance of at least 60 mm between the display case and the wall. 

In  case  of  failure  to  observe  the  above  conditions,  the  display  cases  will  not  meet  their  performance 
characteristics and the power consumption will increase. 
Before using the display cases: carefully remove the protective film from the outer and inner panel surfaces; 
wash  them  with  warm  water  and  neutral  detergent;  rinse;  dry.  When  washing,  prevent  moisture  ingress  in 
electrical items. 
 

 

Содержание 7469.0100

Страница 1: ...Wall Mounted Unit Max 7469 0100 7469 0105 7469 0110 User Manual Gebruikershandleiding Gebrauchsanweisung Le mode d emploi...

Страница 2: ...fications 7 2 1 Scope of delivery 7 2 2 Acceptance certificate 7 3 Proper use 7 3 1 General guidelines 7 3 2 Safety measures 7 3 3 Display case installation 8 3 4 Pre starting procedure of display cas...

Страница 3: ...maximum relative humidity 80 22 C maximum relative humidity 65 25 C maximum relative humidity 60 The temperature range in the useful volume for the display cases without front glazing open is 1 to 7...

Страница 4: ...1 7 0 66 0 27 1955 1075 2040 510 nte L 2500 8 0 4 0 3 25 3 5 2 2 0 86 0 34 2580 1075 2040 610 nte L 3750 12 0 6 0 4 9 5 0 3 1 1 27 0 48 3830 1075 2040 900 nte L FV 1250 3 3 2 0 1 65 1 9 1 2 0 45 0 19...

Страница 5: ...g 2 Rear moulded wall 3 Upper moulded wall top 4 Side moulded or double glazed wall end wall 5 Height adjustable support feet 6 Load bearing posts with perforated panels 7 Shelves with guides and stop...

Страница 6: ...rosting time and frequency are determined by the controller settings The control panel consists of 1 Electronic controller 2 Illuminated key switch Figure 3 Control panel The electronic controller 1 i...

Страница 7: ...of the display cases during their intended use The display case service life and safety in operation depend on observance of the operating rules 3 2 Safety measures The display cases meet the safety...

Страница 8: ...ry package Remove the display case from the wooden pallet by unscrewing the fixing bolts Indoors the product can only be moved in accordance with the handling circuit on the nameplate Tilt the display...

Страница 9: ...ly after the set temperature is reached in the display case interior DO NOT exceed the load limits Warning Products and semi finished products should be pre cooled Products and semi finished products...

Страница 10: ...not installed correctly The refrigeration unit pipelines are in contact with the housing or with each other Adjust the display case installation level using the feet Check the pipeline attachment War...

Страница 11: ...e Centers 5 Storage The display cases should be stored factory packaged not stacked under the conditions of exposure to climatic factors of group 3 acc to GOST 15150 and a temperature of not lower tha...

Страница 12: ...personal protective equipment Shut down the display cases and disconnect the electrical lines before disposal The process liquid oil refrigerant should be removed from the refrigeration system and re...

Страница 13: ...___________________________________________________________________ name of organization ___________________________________________________________________ full name certificate for installation and...

Страница 14: ...lights MVE1 MVE6 Air cooler fans A1 Controller ES Evaporator heating elements Sair S5 NTC temperature sensors YA Timer relay coil Option Display case length mm Number of fans Number of lamps Number o...

Страница 15: ...15 www combisteel com Appendix C normative Refrigerating unit and melt water drain pipeline connection diagram...

Страница 16: ...16 www combisteel com...

Страница 17: ...the compressor according to a signal received from the sensor installed in the air cooler If the interior temperature exceeds the set value the first line in Table 1 then the controller activates the...

Страница 18: ...unit F F r09 Correction of the signal from thermostat sensor 10 10 0 K r12 Manual service 1 stop regulation 0 start regulation 1 1 r13 Displacement of reference during night operation 10 10 0 K r39 Ac...

Страница 19: ...ed sensor type t ntc 5 kOhm ntc 15 Display step 0 5 normal 0 1 at Pt sensor no yes no 16 Maximum hold time after coordinated defrost 20 o46 Cleaning 0 o64 Access code 2 partly access 0 100 0 67 Replac...

Страница 20: ...20 www combisteel com Appendix E Night cover installation instructions Step 1 Step 2 Step 3...

Страница 21: ...21 www combisteel com Step 4 Step 5...

Отзывы: