InteliDrive Lite - 1.2.1 Global guide
181
Setpoint group
Engine protect 2
Related FW
1.2.1
Range [units]
0 - 150 [%]
Default value
10 %
Force value
Step
1 %
Comm object
13178
Related applications
Config level
Standard
Setpoint visibility
Always
Description
Diesel Exhaust Fluid level protection activates LBO DEF Tank Level when received level (J1939 - SCR -
Selective Catalytic Reduction message) is below DEF Level Min for more than (fix) 3s delay. This function
is active for IVECO NEF&&Cursor engine. LBO can be active for running engine only.
DEF Level Min
Setpoint group
Engine protect 2
Related FW
1.2.1
Range [units]
0 - 150 [%]
Default value
90 %
Force value
Step
1 %
Comm object
13379
Related applications
Config level
Standard
Setpoint visibility
Always
Description
Diesel Exhaust Fluid level protection deactivates LBO DEF Tank Level when received level (J1939 - SCR -
Selective Catalytic Reduction message) is above DEF Level Max for more than (fix) 3s delay. This function
is active for IVECO NEF&&Cursor engine.
Note:
DEF Level is usual signage of Urea tank level, which is more often used in United States.
DEF Level Max
10.1.14 Group: ATT Settings
Note:
Following setpoints are available from Controller and LiteEdit/InteliMonitor.