22.
After adjusting the amount of water in the dosing circuit, press the button (15) for adjusting the
detergent percentage supplied by the dosing system (
Fig. 23
).
N.B.
: Set the percentage of detergent present in the dosing system to the maximum value by
pressing the button (15) until the “DETERGENT
PERCENTAGE ADJUSTMENT” symbol
is
completely filled
(Fig. 24
).
23.
Check that the potentiometer knob (16) is set to minimum, otherwise turn it completely counter-
clockwise (
Fig. 25
).
N.B.
: the device will not start to move (either forward or backward) if the potentiometer adjustment
knob (16) is set to minimum.
24.
Lower the brush head unit by pressing the brush head control pedal (17) on the back of the appliance
(
Fig. 26
).
25.
Lower the squeegee unit using the lever (18) on the back of the appliance (
Fig. 27
).
26.
When the dead man's lever (19) is activated (
Fig. 28
), the brush head gearmotor and the vacuum
motor will enter into function. At the same time, the solenoid valve and dosing system will begin
supplying the detergent solution to the brush.
27.
Wait a few minutes, normally 2 – 4 minutes, to allow the dosing system to be washed.
N.B.
: the machine will dispense solution during this operation.
28.
Completely empty the solution tank and the detergent canister (read the paragraph “
THE SOLUTION TANK” and the paragraph “CLEANING THE DETERGENT CANISTER (VERSIONS
”).
22
15
23
24
11
12
25
26
13
27
14
28
CLEANING THE WATER SYSTEM (versions BT - BTS - BTO with PM and CDS system)
Prior to any extended periods of disuse, do the following:
1. Take the device to the dedicated maintenance area.
2.
Take all necessary steps to ensure that the device is in a safe condition (see “
”).
CAUTION
: users are advised to always wear protective gloves, to avoid the risk of serious injury
to hands.
N.B.
: the place designated for this operation must comply with current environmental protection
regulations.
3.
Grip the handle (1) on the left side of the recovery tank (
Fig. 1
) and turn the tank as far as it will go,
until it reaches the maintenance position (
Fig. 2
).
4.
Disconnect the male insert (2) from the female insert (3) present on the cap (4) for the detergent
tank (5) (
Fig. 3
).
N.B.
: before pulling on the male insert, push the lever on the female insert.
5.
Gripping the handle (6) on the detergent canister (5), remove the canister from the compartment in
the solution tank (
Fig. 4
).
6.
Remove the cap (4) from the detergent canister (
Fig. 5
).
7.
Fill the canister with water.
N.B.
: the place designated for this operation must comply with current environmental protection
regulations.
N.B.
: be sure to respect current environmental protection regulations, and never discharge the
detergent directly into the drain.
1
3
2
4
2
3
1
N.B.
: fill with clean water, at a temperature no greater than 50 °C and no less than 10 °C.
8.
Make sure you tighten the cap (4) properly to avoid any liquid leaks during the work activities (
Fig. 6
).
Also make sure that the detergent suction filter (7) is correctly positioned on the bottom of the canister
(
Fig. 7
).
9.
Gripping the canister handle (6), place the canister (5) back in its compartment inside the solution
tank (
Fig. 8
).
10.
Connect the male insert (2) to the female insert (3) present on the cap (4) for the detergent tank (5)
(
Fig. 9
).
11.
Grip the handle (1) on the left side of the recovery tank (
Fig. 10
) and turn the recovery tank as far as
it will go, until it reaches the work position (
Fig. 11
).
12.
Make sure the recovery tank is empty. If this is not the case, empty it (read “
13.
Verify that the quantity of detergent solution in the solution tank is suitable for the type of work you
wish to carry out, otherwise fill the solution tank (see the paragraph “
”). View the level tube (7) at the rear of the machine (
Fig. 12
).
14.
Grip the handle (1) on the left side of the recovery tank (
Fig. 13
) and turn the tank as far as it will go,
until it reaches the maintenance position (
Fig. 14
).
15.
Connect the battery connector (9) to the main system connector (8) (
Fig. 15
).
ATTENTION:
This process must be carried out by qualified personnel.
16.
Grip the handle (1) on the side of the recovery tank (
Fig. 16
).
17.
Turn the recovery tank as far as it will go, to the work position (
Fig. 17
).
18.
For the BT versions, make sure the electronic brake is engaged. If it isn't, turn the lever (10) in the
direction indicated by the arrow. The traction gearmotor is located on the left side of the device
(
Fig. 18
).
19.
Make sure the water tap is fully open: the water adjustment knob (11) should be completely down
(
Fig. 19
).
20.
For the BT versions, bring the main switch (12) to its “I” position by turning the key (13) a quarter
turn to the right
Fig. 20)
).
21.
When the work screen appears on the control display, press the water flow adjustment button (14)
(
Fig. 21
).
N.B.
: Set the amount of water present in the dosing system to maximum by pressing the button
(14) until the “WATER LEVEL ADJUSTMENT” symbol is completely filled (
Fig. 22
).
5
6
4
4
4
5
6
5
6
3
2
8
7
3
2
4
9
1
11
10
7
12
14
13
1
15
9
8
1
16
17
18
10
19
11
13
12
20
14
21
37