background image

 
 

 
 
 

31

 

Treadmill Hardware Manual 1011-0002 v1.02 

 

Press the ODOMETER RESET button on the Treadmill Controller to initialize the odometer to zero or 
load the duration values.  

 

Then press the MODE button accordingly to set the treadmill belt in motion.  

4.5.13 Experiment: Data View 

Once the experiment has started, the screen will display the Data View. The currently selected channel to 
display is in the upper left corner. The channel will be ON if the stimulus is enabled or OFF if it has been 
stopped. The upper right corner will display the various data types and their current value. If the label of the 
data type appears in all upper-case values, then that data type can automatically stop the presentation of 
stimulus. If it appears in all lower-case letters, then it cannot. The bottom line reports the total distance 
traveled by the subject of that channel.  

The CHANNEL knob is used to select one of the active channels and to view its data on the screen. 

The UP/DOWN knob is used to select one of the data types to view. When the stimulus has been automatically 
stopped, an asterisk (*) will appear next to the label of the data type which triggered it. When stopped, the 
current values of all data types for that channel will be frozen for later review.  

If you would like to manually stop the presentation of stimulus for the currently selected channel, then press 
the ENTER button. The channel will toggle from ON to OFF and all the data types will be frozen at their current 

values for review. You may resume the presentation of the stimulus by pressing the ENTER button again. A 
channel that has been automatically stopped cannot be resumed.  

4.5.14 Experiment: Setup View 

Pressing the FUNCTION button will toggle the screen between Data View and Setup View. This screen allows 
reviewing of the experiment parameters while an experiment is running. Use the CHANNEL knob to review all 
the experiment settings. Press the FUNCTION button to return to Data View.  

When the current experiment has finished, use the console controls to copy the important data from the 
screen. Then press the RESET button to discard all results and return to the top of the list of experiment 
parameters.  

 Maintenance  

5.1 Treadmill Belt Tracking 

As the treadmill is used, the treadmill belt and the pulleys will begin to wear in. This may cause the belt to 
stretch and become loose which may also coincide with the belt beginning to track away from the center of 
the treadmill. Adjustments can be made to return the belt to the center of the treadmill. 

 

Remove the treadmill cover and the lane dividers. 

 

Set the SPEED to a high setting, 50.0 meters/minute or greater. 

 

Set the treadmill belt to RUN.  

 

Observe the belt from above the front. 

Содержание Exer 3/6

Страница 1: ...anual June 8 2022 1011 0002 v1 02 950 North Hague Avenue Columbus Ohio 43204 2121 USA Sales sales colinst com Service service colinst com Phone 614 276 0861 Fax 614 276 0529 Toll Free 1 800 669 5011 h...

Страница 2: ......

Страница 3: ...u 19 3 1 Restore Defaults 20 3 2 Serial Number 20 3 3 Run Time Meter 21 3 4 Run Time Odometer 21 3 5 Fan Voltage 21 3 6 Unit ID 21 3 7 Baud Rate 21 3 8 AutoCal Speed 22 3 9 Acceleration Settings 22 3...

Страница 4: ...ntroller User Menu 47 8 1 Restore Defaults 48 8 2 Serial Number 48 8 3 Run Time Meter 48 8 4 Run Time Odometer 48 8 5 Fan Voltage 49 8 6 Unit ID 49 8 7 Baud Rate 49 8 8 AutoCal Speed 49 8 9 Accelerati...

Страница 5: ...dmill Hardware Manual 1011 0002 v1 02 10 1 Treadmill Belt Tracking 59 10 2 Treadmill Belt Tension 59 10 3 Removal of Shocker Assembly 59 10 4 Cleaning 59 Treadmill Types Exer 3 6 Treadmill Modular Tre...

Страница 6: ...odometer distance calibration using the speed sensor Optional Electrical Stimulus up to 2 34 mA 200ms pulse 1 2 or 3 times per second Optional Air Puff Stimulus up to 40PSI 200ms pulse 1 2 or 3 times...

Страница 7: ...9cm 14 5 x 12 0 x 4 3in Physical Weight 4 8kg 10 6lb User Controls 3 x Push Button Rotary Encoders Speed Sensor Connection 6 35mm 1 4in Female Stereo Phone Jack Fan Connections 3 50mm 1 8in Female Mon...

Страница 8: ...receive the same stimuli as the test subjects within an experiment session The Exer 3 6 in Rat mode can support only two channels yoked 1 2 The Mouse mode can support all six channels 1 2 3 4 5 6 1 2...

Страница 9: ...15 pin 1 x Calibration Wand 1 x Instruction Manual 1 x Treadmill Software Flash Drive if using with Oxymax 1 x Exer 3 6 Treadmill shown with optional shock grid 1 x Treadmill Lid 1 x Feces Tray 1 x P...

Страница 10: ...to the Inclination Rod in the hole that is most near the end This end of the Inclination Rod is the bottom Roll the Exer 3 6 on its side Insert the top of the Inclination Rod through the hole in the f...

Страница 11: ...mill came with the Downhill Running Adapter then the system will contain the following 1 x Right leg with rubber foot 1 x Left leg with rubber foot 2 x Braces for the legs 9 x 6 32 x 3 8 in screws 9 x...

Страница 12: ...crews and nuts should hold the pieces closely together but allow them to move Now apply pressure to force the rubber feet of the legs apart and tighten the two screws and nuts near the feet This will...

Страница 13: ...remaining screws and nuts of the legs and braces This completes the assembly of the Downhill Adapter 2 2 3 Air Puff Stimulus The Air Puff Stimulus includes the following 1 x in diameter air supply li...

Страница 14: ...eservoir Place a mark 2 54cm 1in from the end of the 2 4m 8ft air supply line Then fully insert the 2 4m 8ft tube into the air fitting on the rear of the treadmill The mark should be flush with the en...

Страница 15: ...6m 20ft air supply line to the quick connect fitting Connect the 2 circuit valve power cable between the Valve Power port of the Treadmill Controller and the 2 position Molex Mini Fit Jr jack on the...

Страница 16: ...rom the Inclination Rod Now position the treadmill slightly above the new height of the inclination and replace the spring pin into the corresponding hole in the Inclination Rod Slowly lower the tread...

Страница 17: ...l Controller and the 6 position motor cable jack on the Exer 3 6 Treadmill Be sure the locking lever snaps down to secure the cable to the ports Connect the AC power cord to the rear panel AC power re...

Страница 18: ...lus Detection on top of the Treadmill Controller Be sure to center the cabinets feet over the top of the locating pins Using one of the shocker cables connect the Shocker port of the Treadmill Control...

Страница 19: ...UB port on the back side of the treadmill other cables removed for clarity 3 Treadmill Controller User Menu The User Menu is used to set and view various parameters which are saved within the Treadmil...

Страница 20: ...to edit and save any changes Use the SPEED knob to adjust the settings and values while editing 3 1 Restore Defaults The top option on the menu list This is used to restore all the factory settings s...

Страница 21: ...6 Unit ID This option is used to set the CI Bus address of the Treadmill Controller The Unit ID should be unique and not match the address of another device which is connected to the same CI Bus Switc...

Страница 22: ...er will check for a speed output from the Speed Sensor If detected then the calibration procedure will continue if not detected then the screen will display Speed Sensor Not Detected Verify the connec...

Страница 23: ...e three modes of operation are Normal no limits are employed the treadmill belt must be manually stopped Time Limit a count down timer will automatically stop the belt Distance Limit a count down odom...

Страница 24: ...nt 10 000 ohms typical if used Enable the stimulus for mouse lane 1 or 6 by setting the toggle switch on the treadmill toward the lane Install the alligator test leads into the appropriate current mea...

Страница 25: ...RESET button to terminate the experiment and return to the top of the list of experiment parameters Else simply use the CHANNEL knob and navigate to the Mode parameter at the top of the list 2 Press a...

Страница 26: ...and release the ODOMETER RESET button Release the RATE and MODE buttons Use the INTENSITY knob to navigate the menu options Details on each menu option is in SECTION 3 4 3 Loading Subjects Turn the cl...

Страница 27: ...a Time Limit or Distance Limit mode of operation the remaining duration of the session time or distance is displayed When the duration reaches zero the treadmill belt will STOP terminating the exerci...

Страница 28: ...ill persist for two seconds While the stimulus settings are displayed repeated presses of the RATE button will select the next repetition rate in the order of 1Hz 2Hz 3Hz 1Hz etc 4 4 4 Motor Overload...

Страница 29: ...range of 0 to 99 4 5 3 NOACHs Number of Active Channels This should equal the number of subjects to be run in the experiment session Typically this will be up to four channels or eight if yoked The ra...

Страница 30: ...ped when exhaustion has been detected by measuring the percentage of time the subject receives stimulus over a specified rolling period in seconds The period can range from 1 to 180 seconds The percen...

Страница 31: ...you would like to manually stop the presentation of stimulus for the currently selected channel then press the ENTER button The channel will toggle from ON to OFF and all the data types will be froze...

Страница 32: ...solution Do not immerse the treadmill Try to prevent liquids from entering the components as this may damage bearings or the electronics inside Modular Treadmill 6 System Overview The Columbus Instru...

Страница 33: ...CI Bus Connections 8p8c RJ45 Ethernet Modular Jack x2 Shocker Connection 15 pin Female D SUB Motor Connection 6 position Molex 5566 Mini Fit Jr Male Header Belt Speed Range 0 0 102 3 meters minute Acc...

Страница 34: ...ented to each channel lane and the calculate various data outputs from them Yoked Stimulus allows the stimuli delivered to an odd numbered channel to be reproduced on the next even numbered channel Th...

Страница 35: ...th Oxymax 2 x Allen wrench 4 x 3in standoffs may have more for additional lanes 6 x in 20 x 5 8in socket nuts may have more for additional lanes 2 x Lane Base plates may have more for additional lanes...

Страница 36: ...ocket nuts into the two upper holes of one of the base plates Attach two standoffs to the socket nuts Then line up another base plate with the standoffs and attach using another set of socket nuts Att...

Страница 37: ...Hardware Manual 1011 0002 v1 02 Place the support bar in the third slot from the bottom on the front of the running lane base Place base next to motor assembly Do not attach yet Set the running lane o...

Страница 38: ...ly to the standoffs and the coupler between the running lane assembly and the motor assembly Slide the assemblies together with the coupler around both shafts Tighten the coupler screws and the socket...

Страница 39: ...Treadmill Hardware Manual 1011 0002 v1 02 To add extra lanes start with the base assembly right before attaching it to the motor Using two more socket nuts attach one of the additional lane base plat...

Страница 40: ...attach two more standoffs this time screwing the studs into the empty end of the standoffs Now attach another lane base plate using another set of standoffs Place the support bars in the third slot fr...

Страница 41: ...41 Treadmill Hardware Manual 1011 0002 v1 02 Set the running lanes next to each other and attach using the coupler Set the running lanes onto the base...

Страница 42: ...unning base with the motor assembly Line up the standoffs with the holes in the motor assembly and the running lane with the coupler Attach both assemblies together Tighten coupler screws and socket n...

Страница 43: ...on can be increased by moving the support bar to the next slot The slots range from 10 25 in 5 increments 7 3 Connecting Components Make sure that the power switch which is on the controller on the re...

Страница 44: ...to prevent the cable from disconnecting from the motor Connect the other end of this cable in the same manner to the round connector labeled To Motor on the rear of the control unit Connect the AC pow...

Страница 45: ...dmill Stimulus Detection on top of the Treadmill Controller Be sure to center the cabinets feet over the top of the locating pins Using one of the shocker cables connect the Shocker port of the Treadm...

Страница 46: ...ort of the Treadmill Stimulus Detection to the 25 pin male D SUB port on the back of the treadmill lane most close to the motor assembly Physically this lane will be channel 1 other cables removed for...

Страница 47: ...e treadmill lid by tightening the nut To use the fan plug the supplied power cord into the fan receptacle on each lid and plug the other end of the cord into a 110V AC outlet 8 Treadmill Controller Us...

Страница 48: ...ress the ODOMETER RESET button to select this option The screen will display Restore Defaults Are You Sure Press and hold the ODOMETER RESET button to restore the factory settings Else press and relea...

Страница 49: ...an all be used together as a group to control the facilities of one treadmill system The Treadmill Software supports up to four groups The Unit ID of the devices in each group must adhere to the follo...

Страница 50: ...t back on using the switch located near the rear of the controller 8 9 Acceleration Settings This option is used to set the acceleration rate and end speed of the treadmill belt when the treadmill bel...

Страница 51: ...ess the ODOMETER RESET button to reload the timer duration with the time limit and the treadmill belt will run again RUN or ACCELERATION Minutes 0 to 255 minutes up to 4 hours and 15 minutes Seconds 0...

Страница 52: ...ce animal body resistance and AC ammeter Press the ODOMETER RESET button to select the option The screen displays Run to Start Press the MODE button to set the treadmill belt mode to run The screen wi...

Страница 53: ...is the same as those in the Treadmill Controller User Menu 9 Stand Alone General Exercising without the PC 9 1 Stand Alone Initialization Attention Use the following procedure to prevent the applicati...

Страница 54: ...ed by a timer which is preloaded to the duration specified in the User Menu In the Distance Limit Mode indicated by L the odometer is preloaded to the distance duration specified in the User Menu Then...

Страница 55: ...e session Run When the treadmill belt mode is set to RUN the treadmill belt is enabled to move and the speed can be continuously adjusted by the SPEED knob The display will report the set speed and th...

Страница 56: ...loaded into the treadmill and the stimulus intensity and repetition rate should be set Next the experiment is started on the Treadmill Stimulus Detection Finally the treadmill belt is set into motion...

Страница 57: ...nd the total number of visits will be recorded 9 5 6 Max_NOS Maximum Number of Stimuli For humane reasons the presentation of the stimulus can be stopped when the subject has received a set number of...

Страница 58: ...onitoring the stimulus on all enabled channels Press the ODOMETER RESET button on the Treadmill Controller to initialize the odometer to zero or load the duration values Then press the MODE button acc...

Страница 59: ...the nut on the right and loosen the nut on the left If the belt is left of center tighten the nut on the left and loosen the nut on the right Make small adjustments to the nuts only turns and allow 1...

Страница 60: ...mill Hardware Manual 1011 0002 v1 02 Clean the inside of the exerciser with a mild soap solution When cleaning the lids used with metabolic measurement be sure not to expose the fan to the mild soap s...

Отзывы: