Page 30
Ci Scanner Service Manual
6. Disconnect the USB
connection to the board to
allow the PCB Tray to
come off.
7. Disconnect the inline
connector of the mains
cable.
NOTE: These cables go through the
cover with suppressors, the wires are
hard soldered on, and can be easily
broken off, and so great care is needed
when handling this cable. A soldering
iron is required to change the
suppressors, so it is recommended the
PCB Tray is replaced should these
break in the field.
8. Pull out the PCB Tray and
lower enough to be able to
reach the mains connector
to the board without putting
strain on the cable.