Page | 53
VERVE LED
12. “Media not sticking to Bed”
Problematic Parts
Reasons
Correction Steps
1.
Vacuum Pump
Vacuum pump is not ON
Switch ON the Vacuum Pump
2.
Vacuum Settings
Incorrect
vacuum
settings
adjustment
Correct vacuum settings
3.
Run Button on the
Vacuum Regulator
Run button is not pressed after
settings
After adjusting vacuum pump
setting, press the Run button
13. “Print not drying”
Problematic Parts
Reasons
Correction Steps
1.
UV Lamp Settings
UV Lamp settings are incorrect
Correct the UV Lamp settings
2.
Lamp Intensity
UV Lamp Intensity level is low
Control the frequency of UV
Lamp using the Left or Right
Lamp regulator
Set the printing parameters
3.
UV Lamp
UV Lamp is aged
Check and replace, if required
(Contact to factory for more
details)
14. “UV Lamp Shutter Not Working”
Problematic Parts
Reasons
Correction Steps
1.
UV Lamp Settings
UV Lamp settings are incorrect
Correct the UV Lamp settings
Содержание VerveLED VLY 2513
Страница 1: ......
Страница 46: ...Page 45 VERVE LED The Right Calibration Result is shown in the image below Fig 57 The Horizontal Right Check ...
Страница 55: ......