Page | 5
Verve Hybrid
3. Safety Requirements
Before operating the printer and Printer Manager Software for the first time, please read the document
carefully and follow all the usage instructions. While using the printer, kindly follow all the safety instructions
which are given below:
Fire Prevention
Inks and solvents must be enclosed in a special storage cabinet for inflammable liquids or within a separate
storage room and must be clearly identified to meet the professional requirements of safety regulations. Ink
storage must be strictly in compliance with local fire regulations for the use and storage of combustibles.
Ventilation
In order to prevent the danger caused by volatile gas accumulation, the storage room must have sufficient
ventilation.
Note
: Solvent gas specific gravity is greater than the air, it would accumulate near the floor. Installation work
in the vicinity of electrical equipment must confirm the GB/T standards, national electrical regulation
requirements for level II sites, and installation by a corresponding qualification of the professional electrical
contractor.
Software Errors
While using the Printer Manager software, it is possible that some errors may occur. In such case, all the
errors or system messages will be displayed on the Error Information area. Read the error message and try
to resolve it. If you are not able to resolve the issue, please contact us or call at our customer care number
for more assistance.
4. Power Requirements
Before installing the printer, the below mentioned electrical requirements should be confirmed:
•
Machine needs single phase AC 220V power, 30A, 50/60 Hz
•
Machine needs 11KW voltage-stabilizer for machine
•
Uninterrupted power supplies (flicker free) should be provided as it has digital circuit
•
Proper earthing should be required
•
Printer and computer must share same exclusive earthing.
Power requirement for Verve Hybrid is 11KW which is categorized into the following way:
•
2 UV Lamps: each 2.5KW
•
X and Y Servo Driver: 1.5KW
•
24 Power Box 1.35KW (one max 1KW and another one 0.35KW)
•
2 Vacuum Pumps: Each 1.5kw