Page
7
of
50
SOFTJET GRAND
3. Safety Requirements
Power Requirements
Before installing the printer, the below mentioned electrical requirements should be confirmed:
•
Uninterrupted Power supply of 220V, 32Amps (+ / - 10%), 50Hz.
•
Wire gauge to be used should be at least 6sqm, recommended 8sqm.
•
32A MCB required for heater power and 16A for Machine Power.
•
Exclusive Earthing
: It should not be shared with UPS and Building's common Earthing.
•
Printer and computer must share same exclusive Earthing.
Proper Earth Connection
The trouble-free printing depends on the earth connection provided to the machine. In some cases,
the media generates static and excessive charges that can damage the Print Head as well as affect the
placement of printing dots. Thus, one should provide the proper earth connection before using the
printer.
Precautions:
•
A separate earth connection should be provided to the machine
•
The earth resistance should be in the range of 4-5 ohms
•
The distance of the PC from the machine should not be more than 2-3 feet
Note
: Ensure that the earth point for the Printer and PC should be same for the safety of interfaces.
Air Supply
Compressed Dry Air with pressure 7 Bar
Computer
Minimum requirement
•
i5 processor (Quad Core)
•
4GB RAM
•
Win7 64bit or Windows 10 OS
•
Human Input Devices (Keyboard & Mouse)
•
HDD/SSD: 200GB or more
•
1 USB 2.0 Port or USB 2.0 Compatible USB 3.0 Port
•
Color monitor with 1600x1024 resolution, 24-bit Colors
Recommended requirement
•
i7 processor (Quad Core)
•
8GB RAM
•
Win7 64bit OS or Windows 10 OS
•
Human Input Devices (Keyboard & Mouse)
•
HDD/SSD: 500GB or more
•
1 USB 2.0 Port or USB 2.0 Compatible USB 3.0
•
Color monitor with 1600x1024 resolution, 24-bit colors