10.331  64.039  key pad Viba/Rota/Biax 
10.332  62.073  Emergency-Stop pushbutton RXV 
10.333  72.198  cable for emergency switch 
10.334  62.074  switching element BZO 
10.338  64.055  plug FK MC 0,5 4polig Raster 2.5 
10.339 62.058 distance 

sleeves 

10.340  50.023  125 DIN washer B 4.3 zn 
10.341  50.825  934 DIN hex nut M 4 galv. 
10.344  64.059  plug FK MCP 1,5 3polig Raster 3.5 
10.345  64.060  plug FK MCP 1,5 4polig Raster 3.5 
10.346  50.017  127 DIN split washer B 4 galv. 
10.347  51.002  7985 DIN oval head screw M 4x10 galv. 
10.349  64.126  door VIBA 25/25V 
10.350  74.026  plexiglass window 465x345x4 V25 R20/30 
10.352  50.835  934 DIN hex nut M 4 galv. 
10.353  51.003  9021 DIN washer D 4,3 zn 
10.354  64.086  actuator bent Viba 25 
10.355  50.943  933 DIN hex screw M4x10 galv. 
10.356  50.023  125 DIN washer B 4.3 zn 
10.357  50.017  127 DIN split washer B 4 galv. 
10.358  64.016  hinge black VIBA 25 
10.359  50.091  self-locking nut M6 galv. F90 
10.360 64.127 magnet 
10.363  74.047  plexiglass window 465x345x4 V25 R20/30 
10.367 64.175 Door 

reinforcement, Hinge 15i/25i/25iV 

10.367  64.105  Door reinforcement, Hinge Viba15/18 
10.368  64.176  Door reinforcement, handle Viba15i/25i/25iV 
10.368  64.106  Door reinforcement, handle Viba15/18 
10.369 64.130 hinge 
10.370  51.076  7991 DIN countersunk socket head hex scr M5x16 
10.371  50.943  933 DIN hex screw M4x10 galv. 
10.374  50.017  127 DIN split washer B 4 galv. 
10.375  51.003  9021 DIN washer D 4,3 zn 
10.376  64.086  actuator bent Viba 25 
10.377  50.942  933 DIN hex screw M 4x14 galv. 
10.378  50.877  933 DIN hex screw M4x12 galv. 
10.379  50.023  125 DIN washer B 4.3 zn 
10.380  74.049  guiding for sliding door compl. V25D/25Dv 
10.381  64.131  carrier guide rail Viba 25D/25Dv 
10.382  62.192  cap for guiding sliding door 
10.382  62.192  cap for guiding sliding door 
10.383  64.132  carrier guide Viba right 25D/25Dv 
10.384  64.133  carrier guide Viba left 25D/25Dv 
10.385  62.535  toothed rack PA Type 
10.386  51.035  1481 DIN rollpin 3x16 
10.387  64.134  Rack rail Viba 25D/25Dv 
10.388  51.026  7991 DIN countersunk socket head hex scr M5x12 
10.389  62.534  spur gear Z 26 compl. 
10.390  50.935  931 DIN hex screw M 6x40 8.9 galv. 
10.391  50.888  934 DIN hex nut M 6 galv. 
10.392  51.019  9021 DIN washer B 6.4 zn 
10.393  64.086  actuator bent Viba 25 

POS Art 

No. 

Designation 

10.394  50.943  933 DIN hex screw M4x10 galv. 
10.395  50.023  125 DIN washer B 4.3 zn 
10.396  50.017  127 DIN split washer B 4 galv. 
10.397  50.045  7985 DIN oval head screw M 4x14 galv. 
10.398  50.084  125 DIN disc Ø 5,3 polyamid 
10.399  50.825  934 DIN hex nut M 4 galv. 
10.400  51.065  7985 DIN oval head screw M 5x14 4.8 galv 
10.401  50.019  127 DIN split washer B 5 galv. 
10.402  50.045  7985 DIN oval head screw M 4x14 galv. 
10.403  74.050  attachment for guide rail compl. B22/33 
10.404  64.136  mounting for main motor R20/30 B22/33 
10.405  74.051  guide rail adapted B22/33 
10.407  74.052  sliding door right compl. V25D/25Dv 
10.408  64.137  mounting for main motor R20/30 B22/33 
10.409  74.054  plexiglass window 445x200x4 V25D/25Dv 
10.411  50.835  934 DIN hex nut M 4 galv. 
10.412  51.003  9021 DIN washer D 4,3 zn 
10.413  74.053  sliding door left compl. V25D/25Dv 
10.414  64.139  sliding door right V25D/25Dv 
10.415  74.054  plexiglass window 445x200x4 V25D/25Dv 
10.417  50.835  934 DIN hex nut M 4 galv. 
10.418  51.003  9021 DIN washer D 4,3 zn 
10.419  50.096  binding head screw M4x10 
10.420  51.076  7991 DIN countersunk socket head hex scr M5x16 
10.421  50.019  127 DIN split washer B 5 galv. 
10.422  50.045  7985 DIN oval head screw M 4x14 galv. 
10.423  51.082  7984 DIN socket head screw M6x8 galv. 
10.424  50.026  127 DIN split washer B 6 galv. 
10.425 64.077 cap 
10.426 64.077 cap 
10.427  74.079  hood compl. Viba 15/18 
10.428  74.080  hood compl. Viba 15i/25i/25iv 
10.429  74.020  hood compl. Viba 25 
10.430  64.107  housing VIBA 25 RAL 7016 
10.431  64.067  hood Viba 25 
10.432  50.069  Sheet-metal nut 4.8 
10.433  50.069  Sheet-metal nut 4.8 
10.434  64.022  grip recess Viba 25 
10.435  64.021  sound proofing panel Viba 25 
10.436  64.021  sound proofing panel Viba 25 
10.437  64.021  sound proofing panel Viba 25 
10.438  51.002  7985 DIN oval head screw M 4x10 galv. 
10.439  50.068  Self-tapping screw 4.8 x 13 zn 
10.440  50.068  Self-tapping screw 4.8 x 13 zn 
10.441 64.141 Flank 

15i/25i 

10.442  64.142  cover top V2A 
10.443  50.069  Sheet-metal nut 4.8 
10.444  50.068  Self-tapping screw 4.8 x 13 zn 
10.445  64.108  cover for control unit Viba 15 
10.446  64.143  cover for control unit Viba 18 
10.447  64.144  cover for control unit RAL 7004 
10.448  64.109  cover for control unit Viba 15i,25i,25iv 

Содержание VIBA 15

Страница 1: ...Edition 2 3 05 Operating and Servicing Manual Shaker Viba 15 Viba 25 Machine number Year of manufacture...

Страница 2: ...Shaker VIBA 15 VIBA 25 Collomix R hr und Mischger te GmbH D 85080 Gaimersheim...

Страница 3: ...xing cycle 12 5 6 Stand by 12 5 7 Triggering the Emergency Stop function 13 5 8 Average mixing cycles 13 6 Program flow 14 6 1 Switching on 14 6 2 Mixing cycle 14 7 The service menu 15 7 1 Activating...

Страница 4: ...cklist 33 10 5 Spare parts list 34 10 6 Exploded drawings 39 10 6 1 Housing 39 10 6 2 Housing VIBA 15 40 10 6 3 Housing VIBA 15 VIBA 25 INOX 41 10 6 4 Housing VIBA 25 42 10 6 5 Housing VIBA 25 DOOR 43...

Страница 5: ...IBA 15 VIBA25 D 85080 Gaimersheim Edition 2 3 05 3 1 Layout drawings 1 1 Machine components Machine components 1 Mixing table 5 Control panel 2 Manual door release 6 Door 3 Clamping plate 7 Loading sh...

Страница 6: ...Shaker VIBA 15 VIBA25 Collomix R hr und Mischger te GmbH D 85080 Gaimersheim 4 Edition 2 3 05 1 2 Variants VIBA 15 VIBA 15 INOX VIBA 25 INOX VIBA 25 VIBA 25 DOOR...

Страница 7: ...EN the clamping unit QUIT stand by mode STOP mixing cycle prematurely ACKNOWLEDGE messages Button I Mixing cycle I works setting 1 00 minutes Button II Mixing cycle II works setting 2 00 minutes Butto...

Страница 8: ...live components that may pose a risk to life and limb 2 1 Proper use The Viba 25 is a stationary shaker for closed tightly closing round rectangular and oval containers made of metal or plastic It can...

Страница 9: ...of the mixing container are suitable Never lift large and heavy containers into the machine by yourself Use only undamaged and sturdy mixing containers If you don t the container may burst The mixing...

Страница 10: ...machine in areas with a potentially explosive atmosphere to use and install non original replacement parts to run the machine for longer than 20 minutes risk of the mixing container bursting 3 1 Safe...

Страница 11: ...ine runs as smoothly as possible always set the machine feet as low as possible 4 2 Removing the transport brace The mixing unit is secured by a lashing strap to protect it from damage in transit This...

Страница 12: ...ome to rest on the floor You can now push the machine along on its rollers with ease 4 5 Manual door release The door of the VIBA Shaker comes with a safety interlock The door is locked when a mixing...

Страница 13: ...se items from the inside of the machine If the machine wobbles while it is working adjust the machine feet to compensate the differences in height It is prohibited to operate the machine on its shipme...

Страница 14: ...aturely before the selected mixing time is over by pressing button E The mixing cycle is ended as normal The clamping plate opens and the door interlock is released The machine is then ready for the n...

Страница 15: ...released You can then remove the container CAUTION The Emergency Stop button only interrupts the program flow The machine is not disconnected from the mains supply Therefore before performing any mai...

Страница 16: ...to be in the basic display to start a mixing cycle Ready 1 00 2 00 3 00 Select the cycle with the mixing time required by pressing button I II or III The corresponding mixing times are indicated in th...

Страница 17: ...accept no warranty claims or liability for any damage due to changes to the parameters 7 1 Activating the service menu The service menu is activated by repositioning jumper ST8 on the control pcb Cau...

Страница 18: ...physical variable can be determined through the assignment tables in the menu description See 7 4 Setting the operating parameter C Parameters Setting for clamping pressure or electric current consum...

Страница 19: ...IME 3 3 00 7 4 3 only VIBA 25 SMALL POT HEIGHT 220 Low high clamping pressure changeover point 7 4 4 Open and close mixing unit by hand DC MOT FREERUN 3 CLS OPEN 7 4 5 Mixing unit end position DC MOT...

Страница 20: ...ed TEST OUTPUTS M_DOOR Press button E to call up the next menu point 7 4 2 Changing the mixing times TIME 1 3 Buttons I II and III can be assigned 3 different mixing times The works settings can be ch...

Страница 21: ...nu point DC MOT CLAMP HIGH see 7 4 7 The changeover point between low and high clamping pressure is set with the value SMALL POT HEIGHT The set value equals the opening of the mixing unit in millimete...

Страница 22: ...her value for DC MOT ENDPOS means a higher level of electric current consumption and hence force of the clamp motor The value should not be set too high however or the threaded spindles may jam Please...

Страница 23: ...e container working loose during the mixing cycle and wandering on the mixing table Too high a clamping pressure setting may cause the container to burst Setting the correct clamping pressure Load the...

Страница 24: ...4 6 DC MOT CLAMP HIGH 3 CLS 75 OPEN EDIT Change the high clamping pressure Button I CLS close the mixing unit Button II OPEN open the mixing unit Button III EDIT edit the parameter DC MOT CLAMP HIGH 3...

Страница 25: ...ped in place Press button II ON to start the motor SHAKER MOT ON ON OFF The motor runs until you press button III OFF SHAKER MOT OFF ON OFF Press button E to call up the next menu point 7 4 9 Saving c...

Страница 26: ...lf test routine follows after switch on Display of the software version Collomix VIBA init Version X XX d 40 c 80 25 220 Display of d DC MOT ENDPOS c CLAMP HIGH LOW SMALL POT HEIGHT Display of mixing...

Страница 27: ...d Function 1 1 2 3 4 2 clamp motor ST 6 Lead Function 1 brown 2 brown 230V AC to the transformer 3 black L1 4 blue N mains 5 green yellow PE ST 10 Leitung Funktion 1 wei 2 3 4 wei emergency stop ST 14...

Страница 28: ...its two contact faces is parallel to the end face of the proximity switch Set the proximity switch a distance of approx 1 5 mm from the rotary pulse encoder Fix the proximity switch in place with the...

Страница 29: ...ks the door as soon as the mixing cycle is started Releasing the safety door interlock Remove the plastic plug cap from the left side of the machine Use a screwdriver to push the release button of the...

Страница 30: ...11 234 is mounted underneath the oscillating frame The motor used is an asynchronous motor with a capacitor 10 269 It is connected to ST3 on the pcb 10 313 and operated at constant voltage speed The c...

Страница 31: ...eave the machine unattended when open be sure to disconnect the machine from the power supply by pulling out the power plug 9 1 Cancelling messages The VIBA Shaker features intelligent error diagnosti...

Страница 32: ...ntrol pcb is defective 230 V 24 V Ready 1 00 2 20 3 00 Connector for control buttons in wrong position buttons do not work 230 V 24 V Door open Close door Check the 24 V fuse Check the connector cable...

Страница 33: ...P button Check the lead connector to the EMERGENCY STOP button E025 door not locked The door has been unlocked by hand Lock the door by hand The door has not been unlocked by hand Check the door inter...

Страница 34: ...R 2 Plus Important Never clean the machine with a high pressure cleaner or the like This could wash the lubricating grease out of the ball bearings leaving them to run dry and resulting in serious dam...

Страница 35: ...nd tension Check the flange and pedestal bearings of the crankshaft for wear Check the shock absorbers Check the upper and lower spindle bearings Check the toothed belt of the clamp motor for ear and...

Страница 36: ...screw M 4x12 galv 10 271 50 017 127 DIN split washer B 4 galv 10 272 50 023 125 DIN washer B 4 3 zn 10 273 51 099 7985 DIN oval head screw M 4x20 galv 10 274 50 820 934 DIN hex nut M 3 galv 10 275 50...

Страница 37: ...931 DIN hex screw M 6x40 8 9 galv 10 391 50 888 934 DIN hex nut M 6 galv 10 392 51 019 9021 DIN washer B 6 4 zn 10 393 64 086 actuator bent Viba 25 POS Art No Designation 10 394 50 943 933 DIN hex scr...

Страница 38: ...IBA 25 11 220 64 150 crankshaft arm right VIBA 25 11 221 50 841 914 DIN threaded pin M 8x16 galv 11 222 64 007 crankshaft pin VIBA 25 11 223 69 020 pedestal bearing RASEY 30 POS Art No Designation 11...

Страница 39: ...ba 25 230 V 0 9 kW 11 337 64 171 sliding bearing 11 338 62 060 Cable conduit POS Art No Designation 11 339 64 118 Fixation for clamping motor Viba 15 18 11 340 51 097 7985 DIN oval head screw M 4x20 g...

Страница 40: ...t M 10 galv 11 410 50 067 self locking screw M6x12 8 8 11 411 50 091 self locking nut M6 galv F90 11 412 69 019 flange bearing UCF 204 POS Art No Designation 69 026 flange bearing RAY 20 11 413 50 089...

Страница 41: ...Collomix R hr und Mischger te Gmbh Shaker VIBA 15 VIBA25 D 85080 Gaimersheim Edition 2 3 05 39 10 6 Exploded drawings 10 6 1 Housing...

Страница 42: ...Shaker VIBA 15 VIBA25 Collomix R hr und Mischger te GmbH D 85080 Gaimersheim 40 Edition 2 3 05 10 6 2 Housing VIBA 15...

Страница 43: ...Collomix R hr und Mischger te Gmbh Shaker VIBA 15 VIBA25 D 85080 Gaimersheim Edition 2 3 05 41 10 6 3 Housing VIBA 15 VIBA 25 INOX...

Страница 44: ...Shaker VIBA 15 VIBA25 Collomix R hr und Mischger te GmbH D 85080 Gaimersheim 42 Edition 2 3 05 10 6 4 Housing VIBA 25...

Страница 45: ...Collomix R hr und Mischger te Gmbh Shaker VIBA 15 VIBA25 D 85080 Gaimersheim Edition 2 3 05 43 10 6 5 Housing VIBA 25 DOOR...

Страница 46: ...Shaker VIBA 15 VIBA25 Collomix R hr und Mischger te GmbH D 85080 Gaimersheim 44 Edition 2 3 05 10 6 6 Door VIBA 15 and VIBA 15 25 INOX...

Страница 47: ...Collomix R hr und Mischger te Gmbh Shaker VIBA 15 VIBA25 D 85080 Gaimersheim Edition 2 3 05 45 10 6 7 Door Viba 25...

Страница 48: ...Shaker VIBA 15 VIBA25 Collomix R hr und Mischger te GmbH D 85080 Gaimersheim 46 Edition 2 3 05 10 6 8 Door Viba 25 DOOR...

Страница 49: ...Collomix R hr und Mischger te Gmbh Shaker VIBA 15 VIBA25 D 85080 Gaimersheim Edition 2 3 05 47 10 6 9 Sliding door guide Viba 25 DOOR...

Страница 50: ...Shaker VIBA 15 VIBA25 Collomix R hr und Mischger te GmbH D 85080 Gaimersheim 48 Edition 2 3 05 10 6 10 Mixing frame Viba 15...

Страница 51: ...Collomix R hr und Mischger te Gmbh Shaker VIBA 15 VIBA25 D 85080 Gaimersheim Edition 2 3 05 49 10 6 11 Mixing frame Viba 25...

Страница 52: ...Shaker VIBA 15 VIBA25 Collomix R hr und Mischger te GmbH D 85080 Gaimersheim 50 Edition 2 3 05 10 6 12 Clamp motor VIBA 25...

Страница 53: ...Collomix R hr und Mischger te Gmbh Shaker VIBA 15 VIBA25 D 85080 Gaimersheim Edition 2 3 05 51 10 6 13 Oscillating frame Viba...

Страница 54: ...Shaker VIBA 15 VIBA25 Collomix R hr und Mischger te GmbH D 85080 Gaimersheim 52 Edition 2 3 05 10 6 14 Drive Viba...

Страница 55: ...Collomix R hr und Mischger te Gmbh Shaker VIBA 15 VIBA25 D 85080 Gaimersheim Edition 2 3 05 53 10 6 15 Control unit...

Страница 56: ...e paid to our factory Collomix reserves the right to decide on whether cost free parts replacement is applicable Parts and labor covered by the warranty will be supplied free of charge The warranty do...

Страница 57: ...ration of CE conformity We declare herewith that this product conforms with the following standards and standard setting documents EN 292 1 EN 292 2 EN 294 EN 349 EN 954 1 EN 55011 61000 6 2 61000 4 2...

Страница 58: ...omix R hr und Mischger te GmbH D 85080 Gaimersheim 56 Edition 2 3 05 Collomix R hr und Mischger te GmbH Daimlerstr 9 D 85080 Gaimersheim Federal Republic of Germany Tel 49 0 8458 32 98 0 Fax 49 0 8458...

Отзывы: