Shaker
V
IBA
15
&
V
IBA
25
Collomix Rühr- und Mischgeräte GmbH
D-85080
Gaimersheim
14
Edition
2.3-05
6.
Program flow
6.1
Switching on
After being switched on with the main switch the VIBA Shaker first carries out a
self-test and initializes the control system. For further details see chapter 6.
•
Display of software version
Collomix Shaker init
Version X.XX
•
•
Display of system-internal parameters
d=55
c 80 / 25 / 160
•
•
Display of mixing cycles performed so far
Collomix Shaker init
000011 cycles
•
•
Basic display when no faults are active. The
mixing cycle can be started.
Ready
1:00 2:00 3:00
6.2
Mixing cycle
•
You have to be in the basic display to start a
mixing cycle.
Ready
1:00 2:00 3:00
•
•
Select the cycle with the mixing time required by
pressing button I, II or III. The corresponding
mixing times are indicated in the display above
the buttons.
•
•
The selected mixing time is indicated in the LCD
display. The container (pot) is being clamped.
Mixing t = 1.00
clamping
•
•
Clamping of the container (pot) is completed.
Mixing t = 1.00
pot clamped 80
•
Mixing t = 0.59
mixing
•
The mixing cycle begins. The time remaining to
the end of the mixing cycle is indicated on the
right in the display .
•
•
The mixing time has elapsed and the cycle has
ended.
Mixing t = 0.00
wait
•
•
The container is being unclamped.
Mixing t = 0.00
unclamping
•
Ready
1:00 2:00 3:00
•
The door can be opened and the container
removed. The VIBA Shaker is ready for the next
mixing cycle.