Collomix Rühr- und Mischgeräte Gmbh
Shaker
V
IBA
15
&
V
IBA
25
D-85080 Gaimersheim
Edition
2.3-05
21
7.4.6
Setting the low clamping pressure
(DC-MOT CLAMP LOW)
*only VIBA 25
The clamping pressure, i.e. the force with which a container is held between the
clamping plates, can be set with the parameters DC-MOT CLAMP LOW and DC-MOT
CLAMP HIGH.
The value set with DC-MOT CLAMP LOW is used to clamp containers which are smaller
than the value set under SMALL POT HEIGHT (see 7.4.3). Larger containers are clamped
with the clamping pressure set under DC-MOT CLAMP HIGH.
The electric current consumption of the clamp motor is monitored during the clamping. If
it rises above the set limit value, the motor will be switched off.
Too low a clamping pressure setting may result in the container working loose during the
mixing cycle and "wandering" on the mixing table.
Too high a clamping pressure setting may cause the container to burst.
Setting the correct clamping pressure:
Load the biggest container and keep on increasing the clamping pressure until the
container is securely held during mixing.
To check whether the container wanders during mixing, mark the circumference of the
container with a felt pen prior to mixing.
Proceed in the same way with a small container.
The works setting for low clamping pressure is 220 kg. To reduce stress on the
container, set as low a clamping pressure as possible
. Always use original material
in an original container when setting the clamping pressure.
DC-MOT CLAMP LOW
+ 20 -
•
Change the low clamping pressure
•
DC-MOT CLAMP LOW
+ 25 -
•
•
DC-MOT CLAMP LOW
+ 25 -
•
Set the clamping pressure by changing the
parameter:
Button I ( + ):
increase the value
Button II ( - ):
decrease the value
•
•
Press button “E“ to call up the next menu point.