Setting the end stop of the mixing unit
(DC-MOT ENDPOS)
The mixing unit is opened and closed by means of a DC motor whose electric current
consumption is monitored.
When the end position is reached, the electric current consumed by the motor exceeds
the value set for the electric current threshold and the clamp motor is switched off.
The parameter set by the manufacturer for the end stop was selected so that the mixing
unit reliably adopts the end positions without being switched off beforehand.
Before you change the parameter "DC-MOT ENDPOS", check whether the threaded
spindles are dirty or damaged. If necessary, clean and apply grease to the spindles as
described in the maintenance instructions in the manual.
A higher value for "DC-MOT ENDPOS" means a higher level of electric current
consumption and hence force of the clamp motor. The value should not be set too high,
however, or the threaded spindles may jam.
Please note that the electric current threshold of "
DC-MOT ENDPOS
" has
no impact on
the clamping pressure
. The clamping pressure is set in the menu point "DC-MOT
CLAMP HIGH" (see 7.4.6) and "DC-MOT CLAMP LOW" (see 7.4.7).
DC-MOT ENDPOS 3
CLS 30 OPEN EDIT
•
•
Set the electric current threshold for opening
and closing the mixing unit
Button I (CLS):
close the mixing unit
Button II (OPEN): open the mixing unit
The mixing unit opens or closes until the electric
current threshold is reached.
Button III (EDIT): edit parameter
•
DC-MOT ENDPOS
+ 40 -
•
•
DC-MOT ENDPOS 3
+ 42 -
•
Set the electric current threshold so that the
mixing unit reliably adopts the upper and
lower end position:
Button I ( + ):
increase the value
Button II ( - ):
decrease the value
•
•
Press button “E“ to return to the main menu
•
DC-MOT ENDPOS 3
CLS 42 OPEN EDIT
•
•
Press button “E“ to call up the next menu point.
•