MVS-8602 and MVS-8602e Base Configuration
Camera Connections
Follow the rules below to determine which camera port to use on the MVS-8602 and
MVS-8602e (two-camera port frame grabbers) to connect base configuration Camera
Link cameras.
•
Connect a single
area scan
camera to either camera port. Cognex recommends
using camera port 0 first, but this is for clarity when using Cognex software, not a
requirement of the hardware.
•
Connect a single
line scan
camera only to camera port 0.
•
When using one line scan and one area scan camera, connect the line scan camera
to camera port 0 and the area scan camera to camera port 1.
•
When using
line scan
cameras, you must specify the appropriate software I/O
configuration to specify whether you are using an LVDS encoder or TTL (open
collector) encoder. For VisionPro, this means editing the
visionpro.ini
configuration
file; for CVL, this means instantiating the appropriate
ccIOConfig
-derived class.
•
You must use the I/O cable that matches the software I/O configuration, as shown
in Table 3 on page 31.
MVS-8602e Medium Configuration Camera
Connections
Medium configuration cameras have two MDR-26 connectors that you must connect to
the MVS-8602e frame grabber using two of the cables listed on page 24. It is important
which camera connector is connected to which MVS-8602e camera port. The camera
connectors will be labeled with a low and high designator. For example, 0 and 1, or 1
and 2.
Содержание MVS-8000 Series
Страница 1: ...Cognex MVS 8000 Series MVS 8600 Hardware Manual September 2012...
Страница 6: ...Contents 6 MVS 8600 Hardware Manual...
Страница 10: ...Preface 10 MVS 8600 Hardware Manual NOTES...
Страница 42: ...MVS 8600 Installation 1 42 MVS 8600 Hardware Manual...
Страница 78: ...MVS 8600 Hardware 2 78 MVS 8600 Hardware Manual...