MVS-8600 Hardware
2
70
MVS-8600 Hardware Manual
Cables from MVS-8600 to I/O Module
The cable you use to connect the Hirose port to the I/O connection module corresponds
to the currently loaded software I/O configuration, as described in
on page 31. Table 23 summarizes the I/O configuration options and
corresponding cables.
Each parallel I/O cable from Table 23 enables the appropriate set of connections jacks
on the I/O module. LEDs associated with the enabled jacks are illuminated when the PC
containing the frame grabber is powered on. The LEDs for jacks J2 and J3 are
illuminated with all cables.
Note
For all three I/O cables, the board jumpers S1 and S2
must
remain
in their factory default positions for the correct voltages to appear on
jacks J2 and J3 of the I/O connection module. The jumpers are
described in
Power Output Selection Jumpers S1 and S2
The use of each jack on the I/O connection module is described in Table 24 on page 71.
Terminal Block Torque
Maximum 0.8 (7) N-M (in-lbf)
Environmental
Operating Temperature: 0 to 50° C
Storage Temperature: –20 to 85° C
Relative Humidity: 5 to 95 percent
non-condensing
Specification
Description
Table 22. I/O connection module specifications
Cognex
Cable
Software
I/O Config
Camera and Encoders
Supported
I/O Module Jacks
Enabled by this Cable
300-0539
1
Area scan cameras or line
scan cameras with LVDS
encoder, or two line scan
cameras with a shared
encoder
J6, J7, J8, J10
300-0540
2
Line scan cameras with TTL
encoders
J5, J6, J8, J10
300-0538
3
Two line scan cameras with
LVDS encoders
J7, J9
Table 23. PIO cables to connect MVS-8600 to I/O connection module
Содержание MVS-8000 Series
Страница 1: ...Cognex MVS 8000 Series MVS 8600 Hardware Manual September 2012...
Страница 6: ...Contents 6 MVS 8600 Hardware Manual...
Страница 10: ...Preface 10 MVS 8600 Hardware Manual NOTES...
Страница 42: ...MVS 8600 Installation 1 42 MVS 8600 Hardware Manual...
Страница 78: ...MVS 8600 Hardware 2 78 MVS 8600 Hardware Manual...