MVS-8600 Hardware
MVS-8600 Hardware Manual
57
Caution
When using the Cognex I/O connection module (part number
800-5885-1), jumpers S1 and S2
must
remain in their factory default
positions.
The following table shows the meanings of the jumper setting positions.
Jumpers S3-S10
Jumpers S3 through S10 are reserved for future use. You should leave these jumpers
set in the factory default position as shown in Figure 19 below.
Figure 19. Jumpers S3-S10 factory default settings
Resettable Fuses
There are no user-replaceable fuses on MVS-8600 series frame grabbers.
Lines of the power input connector P8 are protected by PolySwitch resettable fuses.
If an over-voltage or over-current condition occurs on these lines, the PolySwitch fuse
trips, opening the circuit. You only need to remove the device that caused the condition,
correct the overcurrent condition, wait a few minutes for the PolySwitch circuitry to cool
down, then plug the device back in. The fuse resets itself.
Jumper over +5
Jumper over +12
S1
+5 V for V_CAM0 (default)
+12 V for V_CAM0
S2
+5 V for V_CAM1
+12 V for V_CAM1 (default)
cc
-
cc
+
S3
S4
S5
S6
cc
-
cc
+
S7
S8
S9
S10
Camera Port 0
Camera Port 1
Note
: Use only these
default settings