Connecting Strobes
Strobes for I/O Options 1 and 2
For I/O connection options 1 and 2, you can wire your strobe device either to the TTL
pins or to the opto-isolated pins on the I/O connection module. The choice between TTL
and opto-isolated wiring is independent of the currently loaded I/O configuration option.
Use the pins described in Table 6 and illustrated in Figure 13.
Signal names are explained in
Figure 13. Strobe wiring for I/O options 1 and 2
A larger view of the top plate of the I/O connection module is in Figure 24 on page 71.
TTL
Opto-isolated
Strobe for camera port 0
S0, GND
S0+, S0–
Strobe for camera port 1
S1, GND
S1+, S1–
Table 6.
Strobe wiring for I/O options 1 and 2
ENCODERS
TTL I/O
LVDS 0
LVDS 1
TTL 1 TTL 0
OPTO 0
OPTO 1
STROBES / TRIGGERS
GND
CHASSIS GND
COGNEX
J3
J2
J6
J5
J8
J7
J10
J9
J1
J11
J4
+12V POWER OUTPUT
+5V POWER OUTPUT
STRB/TRIG0 STRB/TRIG1
A/B 0
A/B 1
STROBE 0 TRIGGER 0
A/B 0
STROBE 1 TRIGGER 1
A/B 1
+12v
S0 T0
S1 T1
S0+ S0-
TO+ T0-
S1+ S1-
T1+ T1-
A0 B0
A1 B1
A0+ A0-
BO+ B0-
A1+ A1-
B1+ B1-