Specifications
8405
Dimensions
31.0mm (1.22in) x 31.2mm (1.23in) x 71.6mm (2.82in).
Weight
Vision system with no accessories attached: 78 g (2.75 oz.)
Case Temperature
1
0°C to 50°C (32°F to 122°F)
Storage Temperature
-20°C to 80°C (-4°F to 176°F)
Humidity
< 80% non-condensing
Protection
IP30 with cables and lens attached.
Shock (Shipping and
Storage)
IEC 60068-2-27: 18 shocks (3 shocks in each polarity in each (X, Y, Z) axis) 80 Gs (800m/s
2
at
11ms, half-sinusoidal)
Vibration (Shipping
and Storage)
IEC 60068-2-6: vibration test in each of the three main axis for 2 hours @ 10 Gs (10 to 500 Hz
at 100m/s
2
/ 15mm)
Regulations/Conformity CE, FCC, KCC, TÜV SÜD NRTL, EU RoHS, China RoHS
1
To verify case temperature, use the EV GetSystemConfig(“Internal.Temperature”) Extended Native Mode command or GetSystemConfig
(“Internal.Temperature”) spreadsheet function. When issued, it returns the vision system's internal temperature in degrees Celsius, which is
±5 degrees above the vision system case temperature. Refer to the
In-Sight
®
Explorer Help
file for more information.Additional cooling
measures are required if the case temperature cannot be kept below 50°C. Examples of such measures include: mounting the vision system to
a heat sink using the M3 mounting screws, reducing the ambient temperature and ensuring there is air flow over the vision system.
28
Specifications