Connect the CIO-MICRO I/O Module (Optional)
The following steps illustrate how to connect the vision system to the In-Sight CIO-MICRO I/O module.
Note
:
l
The CIO-MICRO I/O module supports In-Sight 8000 series vision systems with firmware version 5.3.0 and
higher.
l
The In-Sight 8505P vision system must be connected to a Class 0, 3 or 4 PoE power source, rated for at
least 12.95 Watts. The CIO-MICRO I/O module is a Class 2 PoE device and therefore cannot be used to
supply power to the In-Sight 8505P vision system via the I/O module's PoE port. Instead, connect the
In-Sight 8505P vision system's Ethernet cable to a Class 0, 3 or 4 PoE power source and establish a
connection to I/O module over the local area network using In-Sight Explorer. For more information, see
.
l
I/O wiring or adjustments to I/O devices should be performed when the vision system is not receiving power.
CAUTION
:
Never connect the I/O module to a power source other than 24VDC. Any other voltage creates a risk of
fire or shock and can damage the hardware. Do not connect the 24VDC power source to any terminals other than
the 24VDC + and – power terminals.
1. Verify that the 24VDC power supply is unplugged and not receiving power.
2. Use a screwdriver to loosen the I/O module's power terminals (labeled 24VDC + and –).
3. Insert the 24VDC + and – wires (16 - 22 AWG, solid or stranded wire) from the power supply into the 24VDC +
and – terminals on the I/O module.
4. Tighten the screw terminals with the screwdriver to secure the wire leads in the terminal block; the maximum
torque is 0.1921 Nm (1.7 in-lb).
16
Installation