3.
Locate the ballast inside the base.
3.
Cables
32
and
34
determine the operating voltage. Move them to the required voltage, 208, 230 or 240V on the ballast.
4.
Cables
43
and
49
determine the operating frequency. Move them to the required frequency, 50 or 60Hz on the ballast.
Refer to the stickers on the ballast to ensure correct selection is made.
5.
Locate the trasformer in the base.
6.
Select the voltage from 208, 230 or 240V by moving cable n°
48
to the required voltage. Refer to the sticker on the transformer to
ensure correct selection is made.
7.
When you have made the necessary changes, reposition and refasten the covers and screw as per their original position.
To ensu-
re that the fixtures protection rating is maintained, ensure that the cover is fitted and seated correctly and the screws
tightened firmly, avoiding damage to the silicone seal.
ATTENTION!!
Cable number 39 must not have its position altered under any circumstances.
The 100V and 115V voltages indicated on the transformer cannot be used.