11.4. Electronic motor alignment
The display panel of the
Panorama Power MK2
allows for the electronic alignment of the projector’s motors in the optical system. This
procedure is performed by coemar at the factory. It may be useful to perform this procedure in the case of internal components being
replaced.
Altering the factory settings may radically alter the functioning of the projector. Carefully read all of the following prior to attempting any
changes.
Electronic calibration
1.
Press the
menu button and then enter to confirm.
2.
Press the
+
or
-
button until
FUNC
is displayed. Then press
enter.
3.
Press the
+
or
-
button until
RESE
is displayed.
4.
Press the
enter
and menu buttons simultaneously, holding them for at least
10"
. The motors will perform a reset and the display will show
-- -- -- --
for a few seconds. After this, the display will show
DIMM
confirming that you have entered electronic calibration mode.
5.
Press the
+
or
-
button until the motor you wish to align is displayed and then press the enter button.
6.
Press the
+
or
-
button until the correct calibration value is displayed and then press the enter button.
Simultaneously pressing the
+
and
-
buttons to return the calibration value to 128 (default).
7.
To exit calibration mode press
+
or
-
button until
END
is displayed and confirm this by pressing
enter.
The following diagram displays the menu navigation system.
11.5. Resetting the counter
The lamp life counter needs to be reset to zero at every lamp change to provide accurate information on lamp life. To do this you will
need to access the calibration menu (see section
11.4 Electronic motor alignment
). The following are the required steps:
1.
Press the
menu
button and then press
enter
.
2.
Press the
+
or
-
buttons until
FUNC
is displayed. Confirm this by pressing enter.
3.
Press the
+
or
-
buttons until
RESE
is displayed.
4.
Press the
menu
and
enter
buttons simultaneously, hodling them pressed for about 10 seconds. The unit’s motors will perform a resetand
the display will show
-- -- -- --
for a few seconds. At the end of this, the display will show
DIMM
confirming you have entered calibration
mode.
5.
Press the
+
or
-
buttons until
CL R
is displayed (to access the lamp life counter for the right lamp) and press
enter
.
6.
The display will show
SURE
.
Confirm this by pressing enter.
DIMM
dimmer
Dimmer alignment
CYAN
cyan
Cyan colour alignment
MAG
magenta
Magenta colour alignment
YELL
yellow
Yellow colour alignment
CL L
lamp hour meter reset
To reset the hour meter of left lamp.
The operation is made every lamp change.
CL R
lamp hour meter reset
To reset the hour meter of left lamp.
The operation is made every lamp change.
END
end
To end the electronic setting
procedure and confirm the
recording.
☞
enter
☞
enter
☞
enter
☞
enter
☞
enter
SURE
confirm reset
0 1 2 8
0 1 2 8
0 1 2 8
0 1 2 8
☞
+
o
--
☞
+
o
--
☞
+
o
--
☞
+
o
--
0 1 2 8
0 1 2 0
0 1 6 5
0 1 38
es.
es.
es.
es.
☞
enter
☞
enter
☞
enter
☞
enter
☞
+
o
--
☞
+
o
--
☞
+
o
--
☞
+
o
--
☞
+
o
--
SURE
confirm reset
☞
enter
☞
+
o
--
A 0 0 1
☞
enter
☞
+
o
--
Press together
enter
and
menu
keys for
10 seconds: the display will show this menu
RESE
AOO1
☞
+
o
--
FUNC
☞
+
o
--
☞
menu
ATTENTION!!
The alignment procedure can only be carried out when DMX 512 signal is connected.
ATTENTION!!
This procedure should only be undertaken by qualified and experienced technical personnel.
27