3.
Locate the two lamp assemblies, right and left. Remove the two screws
“C”
which hold the assemblies in place.
5.
Locate the lampholder
“E”
6.
Insert the lamps. The lamp used is manufactured from quartz glass and
should be handled with care; always adhere to the instructions supplied
in the lamp’s packaging. Never touch the glass directly, use the tissue pro-
vided in the lamp’s packaging. The GX 9,5 lampbase is symmetrical in con-
struction. DO NOT USE UNDUE FORCE. In case of difficulty, re-read the
instructions and repeat the procedure.
7.
Replace the lampholder assembly in its original position and refasten the screws which were previously removed.
8.
Repeat the procedure for the second lamp.
ATTENTION!!
Each time you change the lamp, we recommend the following be carried out:
• realign the lamp in the optical path to avoid overheating dichroics and dimmer.
• reset the lamp life counter (as described in section 11.5. Resetting the counter).
24