IP5000 2.0 Series
Administrator Guide
CONFIGURING DIAGNOSTICS
Diagnostic Settings
The IP5000 speakerphone diagnostic settings are configured by:
•
Selecting Diagnostic Settings in the Code Blue Configuration.
•
Click the Enable check box.
•
Input the SNMP Server IP address and SNMP Server Port number to monitor the IP5000 with
an SNMP management software or with Code Blue’s ToolVox
®
Gateway, w/Unit Programming &
Diagnostic (UPD) Software.
Power Supply Failure Timeout
The IP5000 monitors the power sources for loss of power or, in the case of the 12Volt / Battery,
the circuit monitors for Low Voltage condition(11.5 – 11.0V).
Note: Backup power must be available for the phone to report a power failure. If no power is
available, a network management system must periodically check the phone for the power
failure to be reported. Code Blue’s UPD can provide this function.
•
Power supply monitoring is based on the selections made in Hardware Settings > Power Supply
section.
•
12-24 Volt A/C or D/C monitoring will be checked within the time interval provided. (Example:
900 seconds = 15 minutes.) The interval range 0 - 9999999 (1 second - 2,777.7775 hours),
should the voltage become unavailable or a problem has been detected. The
CODEBLUE-
MIB::powerSource
parameter will be issued.
•
Main power MIB value is
CODEBLUE-MIB::powerSource.0 ac
. The SNMP trap will be issued
again if at the next interval the voltage issue has not been rectified within the timed interval
another Trap will be sent. The AC power failure script will also be run.
•
12 Volt D/C - Battery monitoring will check the battery voltage every 900 seconds and report
a voltage condition via a SNMP trap.
•
12V DC battery MIB value is
CODEBLUE-MIB::powerSource.0 dc
. Replace the fully charged
battery if possible. If replacing with an uncharged battery, allow up to 48 hours for a full re
-
charge. The DC power script will also be run.
•
PoE Power Failure: When PoE power is the sole power source and interruption in service is
experienced, no Trap will be sent unless the IP5000 has a second power source to back up the
IP5000 operations.
Note: PoE power failures will only be reported if data service is still available.
•
PoE Power MIB value is
CODEBLUE-MIB::powerSource.0 poe
. The PoE power failure script
will also be run.