Code Blue
•
259 Hedcor Street
•
Holland, MI 49423 USA
•
800.205.7186
•
www.codeblue.com
GU-162-E
page 12 of 56
Centry®
Administrator Guide
5 Wiring Diagram
1 -
Cat 5e - Connect to Switch (100 Mb)
2 -
Cat 5e - Connect to Peripheral (100 Mb)
3 -
Cat 5e - Connect to Peripheral (100 Mb)
4 -
Optional 12V battery
5 -
12V DC power
6 -
Aux outputs (3)
• The auxiliary outputs are Normally Open and can be triggered in your action script to
close. Duration is defined in your action script.
7 -
Aux inputs (3)
• The auxiliary inputs are Normally Open and are triggered by voltage. The voltage range is
9 to 32V AC or DC with current protection of 1.25 Amps.
8 -
Factory Reset Switch
• With power connected to Centry, hold down this reset switch for 12 seconds and then
release. The unit will reboot. All settings will be lost.
Code Blue Corp®
ed-20011-a_Centry_Board_Connections (2).vsd_revised.vsd
Wiring map concept
SIZE
FSCM NO
DWG NO
REV
SCALE
1 : 1
Mike Rose
SHEET
1 OF 1
Engineering Dept
Code Blue
PAS Control
Cable
PoE
WAN
LAN 1
PASAudio
Batt Aux
Pwr
Main
Pwr
Outputs
Inputs
Reset
LAN 2
- + - +
1 1 2 2 3 3 1 1 2 2 3 3
12v DC
? buzzer
Momentary
Trigger
To
P
w
r
Code Blue PAS Amp
Control Plug
RJ-11Audio
Flat Cable to Amp
WAN
PoE enabled
Ethernet
LAN port 1
LAN port 2
Layers have been used on this page.
Do not add anything without checking the layer list
USER’s Connections
1
2
3
4
6
9
8
7
5
8
12 V DC (max 400mA)
Finger Safe header
CAUTION
PCB is sensitive to
static discharge
NOTICE
12V SLA 2 Ah battery
source (max 400mA)
CAUTION
Power over Ethernet
802.3 af/at 37-57V DC
(max 350mA)