Code Blue
•
259 Hedcor Street
•
Holland, MI 49423 USA
•
800.205.7186
•
www.codeblue.com
GU-162-E
page 10 of 56
Centry®
Administrator Guide
What’s Included
Quantity
Part Description
1
Centry
®
Help Point
®
1
Enclosure (Surface or Flush)
4
Security Screws
2
Knockout Covers
1
Faceplate / Circuit board with Integrated IP Color Camera and Beacon Light
Centry faceplate tools needed for installation:
1. Drill and screws to mount unit to wall.
2. T10 pin Torx driver.
Basic Flush Mount Installation Instructions:
1. The flush mount enclosure will come with no mounting holes. It can be mounted from the
sides, top or bottom. Once your mounting needs have been determined, drill the holes
needed for your specific installation requirements into the flush mount back box.
2. Mark the mounting holes onto the mounting surface. In order to comply with the Ameri-
cans with Disabilities Act (ADA) of 1990, the speakerphone button(s) should be positioned
between 34 and 48 inches from grade level. (Consult an ADA specialist in your area to verify
local and federal guidelines.)
3. Connect earth ground to the provided copper grounding lug using a minimum 14 gauge
conductor.
4. Connect electrical and communications wiring using the wiring diagram below.
5. Follow all federal and local codes that apply.
6. Attach faceplate to enclosure using four security screws.
Basic Surface Mount Installation Instructions:
1. Open shipping box and remove Centry unit.
2. Remove four security screws with T10 Torx driver.
3. Separate Centry from enclosure and set aside carefully.
4. Mark the mounting holes onto the mounting surface. In order to comply with the Ameri-
cans with Disabilities Act (ADA) of 1990, the speakerphone button(s) should be positioned
between 34 and 48 inches from grade level. (Consult an ADA specialist in your area to verify
local and federal guidelines.)
5. Drill all marked holes.
6. Secure the housing to the wall – If you are securing to drywall, utilize drywall screws and
anchors. If you are securing to metal, utilize sheet metal screws. If you are securing to brick,
use Tapcon screws. Fasten all screws securely.
Important:
Ensure that conduit is aligned with wiring.