B
Appendix B: Gas Conversion
28
©
Moffat Ltd, August 2012
Revision 3
Moffat Cobra Series CS9 - Gas Salamander
Gas Regulator
- NAT Gas / LPG / Butane Only.
NOTE: The regulator supplied is convertible
between Natural Gas and LP Gas, but
it’s outlet pressure is fixed ex-factory
and is NOT to be adjusted.
1. Ensure that the gas supply is turned 'Off' at
the mains.
2. Unscrew the hexagonal cap (23mm A/F) from
the regulator.
3. Un-clip the plastic pin from the cap, reverse
the pin and re-fit it back to the cap the correct
way for the gas type to be used.
(Either ‘LP’
or ‘NAT’ should be visible on the flank of
the pin once re-fitted to the cap)
.
4. Screw the cap back into the regulator hand
tight only.
- Town Gas Only.
1. Unscrew and remove the slotted cap from the
regulator.
2. Turn on the gas supply and the appliance.
3. Adjust the pressure djusting nut to achieve the
correct burner operating pressure.
NOTE:
The operating pressure to be
measured at the manifold test point
and with both burners operating at
the 'High Flame' setting.
4. Turn off the mains gas supply and bleed the
gas out of the appliance gas lines.
5. Turn on the gas supply and the appliance.
6. Verify the operating pressure remains correct
(Re-adjust the regulator if required).
7. Screw the cap nut back onto the regulator.
NOTE
, Pin rotated
for Natural Gas
NOTE
, Pin rotated
for LPG
Pressure Adjusting
Screw
Cap Nut
Figure b3
Figure b4