2
Installation
7
©
Moffat Ltd, August 2012
Revision 3
Moffat Cobra Series CS9 - Gas Salamander
7.
Check all gas connections for leakages using soapy water or other gas detecting equipment.
8.
Check that the gas operating pressure is as shown in 'Specifications' section.
NOTE: The operating pressure to be measured at the manifold test point and with both
burners operating at the 'High Flame' setting.
9.
Turn off the mains gas supply and bleed the gas out of the appliance gas lines.
10. Turn 'On' the gas supply and the appliance.
11. Verify the operating pressure remains correct (Re-adjust the regulator if required).
Commissioning
1.
Before leaving the new installation;
a. Check the following functions in accordance with the operating instructions specified in the
'Operation' section of the User manual.
Light the Main Burners.
Check the Low Fire burner operation.
Check the High Fire burner operation.
Check the Racking System operation.
b. Ensure that the operator has been instructed in the areas of correct lighting, operation, and
shutdown procedure for the appliance.
2.
The User manual must be kept by the owner for future reference, and a record of
Date of
Purchase,
Date of Installation
and
Serial Number of Unit
recorded and kept with the manual.
(These details can be found on the Rating Plate attached to the R/H side panel (refer to
the 'Gas Connection' section).
NOTE: If for some reason it is not possible to get the unit to operate correctly, shut off the
gas supply and contact the supplier of this unit.
WARNING:
D
O
NOT
USE
A
NAKED
FLAME
TO
CHECK
FOR
GAS
LEAKAGES
.
Содержание CS9
Страница 4: ... Moffat Ltd August 2012 Revision 3 Moffat Cobra Series CS9 Gas Salamander ...