SNMP Configuration Tab 

The BBG-1090-DEC-MPEG includes a built-in SNMP agent with support for SNMP V1 and 
V2C.  It will respond to SNMP transactions only on the control port, for security reasons.  This 
tab includes the parameters for the SNMP configuration.  Changes to these parameters take 
effect immediately. 
 

 

 

The SNMP parameters are as follows: 
 

 

Read Community: 

this is the SNMP Read-Only community string. 

 

Write Community:

 this is the SNMP Read-Write community string. 

 

System Contact:

 this configures the value for the MIB-II System variable System 

Contact.  Whatever value entered here is returned for SNMP queries to that variable. 

 

System Location:

 this configures the value for the MIB-II System variable System 

Location.  Whatever value entered here is returned for SNMP queries to that variable. 

 

Trap Destinations:

 the BBG-1090-DEC-MPEG supports up to 5 trap destinations.  Enter 

the desired IP addresses here.  Note that the BBG-1090-DEC-MPEG will only generate 
SNMP V2C traps. 

 

SNMP Statistics Tab 

The SNMP statistics tab displays the current SNMP configuration. 
 

Содержание 9990-DEC-MPEG

Страница 1: ...Cobalt Digital Inc BBG 1090 DEC MPEG Standalone MPEG4 AVC and MPEG2 Decoder with ASI and IP Inputs and SDI Outputs Product Manual Version 1 0 BBG 1090 DEC MPEG OM Version 1 0...

Страница 2: ...on or reverse engineering of copyrighted software is prohibited Notice The material in this manual is furnished for informational use only It is subject to change without notice and should not be cons...

Страница 3: ...ease contact Cobalt Digital regarding any malfunction or failure of the appliance Electrostatic Discharge ESD and ESD Protection Static electricity can damage boards and other components Before connec...

Страница 4: ...within the equipment manual indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury It may also be used to alert against unsafe practices Notice The sy...

Страница 5: ...age of this manual All Cobalt Digital Inc products are covered by a generous 5 year warranty and will be repaired without charge for materials or labor within this period See the Warranty and Repair P...

Страница 6: ...rk Configuration Tab 20 Network Statistics Tab 21 ASI Input Port 23 ASI Input Configuration Tab 23 ASI Input Statistics Tab 24 ASI Output Port 25 ASI Output Port Configuration Tab 25 ASI Output Port S...

Страница 7: ...55 Network Tab for Color Bars 57 Ancillary Data Tab 57 Configuration Tab 58 IP Outputs Tab 59 IP Outputs Configuration Tab 59 IP Outputs Status Tab 63 Monitoring Tab 65 Monitoring Configuration Tab 65...

Страница 8: ...ds This device complies with EN 61000 3 2 standards This device complies with EN 61000 4 2 standards This device complies with CISPR 22 Edition 6 This device complies with AS NZS CISPR 22 CE Mark Warn...

Страница 9: ...isconnect device and must be approved for the country where it is used For USA and Canada The cord set must be UL approved and CSA certified The attachment plug must be an earth grounding type with a...

Страница 10: ...P RTP SMPTE 2022 auto sensing o RTP ARQ support Cobalt proprietary o HTTP Live Streaming HLS client o RTMP Client mode connects to an RTMP server and plays the content o RTMP Server mode accepts conne...

Страница 11: ...sical input output port such as ASI or Ethernet and stream for a transport stream present in the port ASI ports support only one stream while Ethernet ports support multiple streams A transport stream...

Страница 12: ...ernet port on a standard RJ 45 connector The panels differ only on the type of analog audio output Model BBG 1090 DEC MPEG B is fitted with 3 pin terminal block audio connectors providing balanced ana...

Страница 13: ...signal in the output but it does not correspond to a decoded stream LED flashing once per second the decoder is currently outputting an SD stream on the selected output ports LED flashing multiple tim...

Страница 14: ...SI output rear I O panel indicator VID LED behaves exactly the same as the Video output rear I O panel indicator Ref In LED this LED blinks when the decoder is receiving a genlock signal from the chas...

Страница 15: ...while holding the switch the following actions will be performed The control IP address mask and gateway are reset to the factory defaults as described above The unit configuration is cleared The uni...

Страница 16: ...atistics panel Network this tab is used to configure the IP addresses and network information for the Ethernet ports The statistics side of the panel includes some additional information such as link...

Страница 17: ...17...

Страница 18: ...the firmware revision for the decoding subsystem The format is Major Version Minor Version DSP firmware will only occasionally be updated by Cobalt Digital Inc Serial Number This is the serial number...

Страница 19: ...es centigrade of the air intake of the card measured at the front edge of the card Internal Temperature Temperature in degrees centigrade at the back of the card MDP Core Temperature Temperature in de...

Страница 20: ...ports that are in use only turn it off if you do not plan to connect that port to a network IP Address Enter the desired IP address for this Ethernet port Subnet Mask Enter the desired subnet mask for...

Страница 21: ...mode o 1Gb s Full Duplex restrict the operation to 1Gb s Full Duplex mode Note that the port will still perform auto negotiation but it will only advertise this mode Interface Settings If you make any...

Страница 22: ...eports the current setting for this parameter Port 1 Link This indicator has the following states o Link OK The port has established link with the switch o No Link The port does not currently have lin...

Страница 23: ...and locked to a valid ASI signal Unlocked the port is enabled but has no signal Disabled the port is disabled by user configuration o Size Indicates the detected ASI transport packet size 188 or 204 b...

Страница 24: ...ding LED in the front and back panels stays off Once the desired configuration is entered click on the Apply button to have them take effect This will cause the changes made in the Configuration Param...

Страница 25: ...al transport stream bit rate in bits second Port Name This reports the configured Port Name Edit Button Clicking on this button allows reconfiguration of the port The ASI Port Configuration screen app...

Страница 26: ...Statistics Tab The Statistics Tab for the ASI Output Port provides a quick visual summary status An example is depicted below The ASI Port indicator can have the following values TX OK The port is op...

Страница 27: ...If the decoder is in HLS mode this tab allows for manual configuration of the decoded profile The decoder configuration tab is divided into the following functional areas The Decoder Input configurati...

Страница 28: ...eve a Flash stream from an RTMP Server such as the Adobe Media Server or similar RTMP Server the decoder will accept a Flash stream from a publishing RTMP client RTSP Client the decoder will connect t...

Страница 29: ...n IP Multicast stream When this mode is selected a new field appears for the multicast address o Primary Multicast Address enter the desired IP multicast address The decoder will only accept addresses...

Страница 30: ...ng from the primary it will go to the backup or vice versa Reset Network Statistics button when clicked this button causes the UDP RTP statistics shown in the Network Tab on the Statistics area to be...

Страница 31: ...he round trip delay so the decoder has multiple chances of recovering a lost packet Note however that the value of the NACK window adds to the end to end glass to glass latency NACK Target this parame...

Страница 32: ...rt enter a valid UDP port for the backup stream Valid values are between 1 and 65535 o Flip Redundancy if this button is clicked the Decoder will manually flip to the other stream i e if it is receivi...

Страница 33: ...b in the Statistics area RTMP Client In this mode the decoder can access and play a Flash stream from an RTMP Server such as the Adobe Media Server or similar Note that not all Flash streams are suppo...

Страница 34: ...d port select Specific Port When Specific Port is selected an additional field is displayed Port This field is only displayed if RTMP Port Selection is set to Specific Port Configure a non standard TC...

Страница 35: ...oder will listen on the default RTMP Port TCP Port 1935 If a custom non standard port is desired select Specific Port and a new field will appear for the TCP port Port This field is only displayed if...

Страница 36: ...a few seconds after the stream start the RTSP server may send a synchronization message which is primarily intended to synchronize audio and video Some RTSP cameras will send this even if they do not...

Страница 37: ...se the Decoder Output Configuration controls to specify the desired output frame rate and other video output parameters Decoder Program and Audio Selection This section is only displayed if the Source...

Страница 38: ...shown as Program X where X is the actual program number In the example below Program 1 has a name NBC so it shown as 1 NBC and Program 2 does not have a name so it is shown as Program 2 Program Auto...

Страница 39: ...ue in this case Digital Output Disabled No additional parameters are displayed in this case Both the SDI and the HDMI outputs will be disabled and video will be present only in the composite output Th...

Страница 40: ...selection is available Note also that the Audio 2 Service selection in the Decoder Program and Audio Selection section will disappear in pass through mode Audio 1 Embedded Group Select the group to e...

Страница 41: ...Line Offset By default the Decoder will align the beginning of the video frames between the genlock reference and the SDI output This control allows the offset to be changed by an integral number of l...

Страница 42: ...displayed Select a standard resolution in this case Format This selects the output format It is only relevant if the BBG 1090 DEC MPEG is decoding a Standard Definition SD signal and up converting it...

Страница 43: ...n The decoder converts transport stream SCTE 35 sections back to SCTE 104 VBI ANC and re inserts this data when the box is checked and applied Once this box is checked the following additional control...

Страница 44: ...If any errors are detected an error message is displayed by the Apply button The possible error messages are Error no available IP License the Source parameter in the Decoder Input Configuration is se...

Страница 45: ...am ID TSID For each program an individual header is provided showing the Program Number and the PMT PID Program Name If available the Program Name is displayed If the transport stream contains a Servi...

Страница 46: ...ofile supported by its Internet connection If this is set to Manual the Load buttons in the Select column will become available and a specific profile can be selected Load these buttons can be used to...

Страница 47: ...ram Info Tab for RTMP Client and Server For RTMP Streams the Program Info Tab shows the RTMP Metadata if it has been provided by the client or the server Automatic Profile Selection Manual Profile Sel...

Страница 48: ...decoder configuration Status Tab The Status Tab includes the following information Decoder State if this indicator is green the content is being decoded normally Otherwise it will be red and the stat...

Страница 49: ...s are included in the Status Tab Genlock Status this field can show the following values o OK The genlock function is operating normally and the output is genlocked to the reference o Incompatible Ref...

Страница 50: ...e matrix below indicates what combinations are legal Genlock Compatibility Matrix Network Tab The Network Tab contains protocol specific statistics and changes according to the decoder source selectio...

Страница 51: ...PEG is detecting SMPTE 2022 FEC in Row and Column mode o Not Licensed The SMPTE 2022 functionality is not licensed in this unit see the Admin License Keys Tab If SMPTE 2022 FEC is present it is being...

Страница 52: ...ent Invalid FEC Packets Indicates the count of received FEC packets which have invalid protocol fields If this count is non zero we recommend you contact your encoder vendor The counts for Received Pa...

Страница 53: ...the total number of lost packets that could not be recovered with RTP ARQ because a retransmission for them was never received NACKs Sent indicates the number of retransmission requests sent Note that...

Страница 54: ...Stream configuration area to play it again o Live Stream the stream is live o Event the stream is an event This means that it is finite it has a well defined end The BBG 1090 DEC MPEG will stop playi...

Страница 55: ...f the source In RTMP Client mode this is the IP address of the RTMP Server from which the decoder is pulling the stream In RTMP Server mode this is the IP address of the publishing client RTMP Connect...

Страница 56: ...sed In the example above port 59970 is being used for the video and port 59971 is being used for RTCP Video CODEC This field contains a textual representation of the video CODEC as reported by the ser...

Страница 57: ...is configured for SDI output Closed Captions indicates if closed captions are present or not present in the SDI output SMPTE 2038 indicates if SMPTE 2038 ANC packets are being inserted in the SDI out...

Страница 58: ...Tab shows the current running configuration of the decoder When the Apply button is pressed the changes made in the configuration area are reflected here It follows the same layout as the Decoder Conf...

Страница 59: ...treams automatically pre populated with the programs present in the ASI input in the order they appear in the PAT The most common settings and statistics for each stream are shown in the table below N...

Страница 60: ...in the stream since it was enabled Output Rate This field reports the output rate of the stream If NULL padding is disabled it will match the input rate If NULL padding is enabled it will correspond...

Страница 61: ...ter allows the configuration of the Type Of Service TOS byte in the IP header also known as the Differentiated Services DS field Valid values are between 0 and 255 Configuring this is only useful if t...

Страница 62: ...w and Column mode such receivers will only use the FEC Column data and discard the FEC Row data If either Column Only or Row and Column are selected the following additional controls are displayed Col...

Страница 63: ...ta for short periods of time but the MPEG buffer models may be compromised When the Apply button is clicked the changes entered in the Advanced Configuration area are implemented if the Decoder is lic...

Страница 64: ...t high enough to support the current stream rate Packets are being dropped Either increase the padding rate or set the port to Auto Bit Rate or disable NULL padding Overrun The overall IP output capac...

Страница 65: ...e an alarm and send an SNMP trap if a given PID disappears for more than a configurable amount of time Monitoring Configuration Tab The Monitoring Configuration Tab is divided into two sub tabs The PI...

Страница 66: ...present in the stream are displayed If a PID is initially present and then disappears it will remain in the able until the Reset PID Statistics button is clicked Bit Rate current PID bit rate in bits...

Страница 67: ...l only be raised when the elapsed time from the enable moment exceeds the trigger Elapsed s This field indicates the number of seconds since the PID in this alarm was last seen It is only active if th...

Страница 68: ...68...

Страница 69: ...this tab License Keys Contains the current licensing state of the BBG 1090 DEC MPEG and allows for new license keys to be entered Event Log The BBG 1090 DEC MPEG contains a non volatile event log It c...

Страница 70: ...ry image if it detects a corrupted firmware image The BBG 1090 DEC MPEG has one additional firmware image called the DSP Image The unit can hold up to 4 DSP images DSP images will be rarely updated by...

Страница 71: ...ntroduce any glitches in the inputs outputs The fields in the Firmware Image Management tab are Factory Image Image 1 and Image 2 These contain version and release date information for the correspondi...

Страница 72: ...oot later during a maintenance window Available DSP Images this field has a list of loaded DSP images Admin Config Files Tab As you make configuration changes to the BBG 1090 DEC MPEG they are automat...

Страница 73: ...iguration It is not required but highly advisable The name can be edited at any time even when there is no saved configuration Config Load Button If you click on this button the corresponding configur...

Страница 74: ...rresponding file is downloaded to your computer This feature is provided to allow configuration backups If you save a configuration to your computer and later wish to restore it to the BBG 1090 DEC MP...

Страница 75: ...there may be actual video being displayed9 RTMP Server Mode This template puts the decoder in RTMP Server Mode It will wait for a connection from an RTMP publishing client and display the stream Clea...

Страница 76: ...g field indicates how long until they expire If you do not have temporary licenses this field has the message No active temporary licenses The table columns correspond to the licensable features as fo...

Страница 77: ...ers Invalid Corrupted Key the key you entered has the correct number of characters but it is invalid Double check what you entered Serial number mismatch this key is for serial xxxxxxxxxxxx BBG 1090 D...

Страница 78: ...well Subsystem The subsystem affected by the event This may be a port a stream or the card itself Event This is a textual description of the event None of the BBG 1090 DEC MPEG models have a battery...

Страница 79: ...se to see the last 10 events of any kind by selecting All or you can restrict the view only to Info Warning or Error Event Log This table presents the last 10 events of the selected type Time Zone To...

Страница 80: ...new events after the unit has been set up Note that this action does not clear the logs stored in non volatile memory The BBG 1090 DEC MPEG will store up to about 400 kBytes of logs in non volatile m...

Страница 81: ...tabs Control Port is used to configure the IP parameters of the control port SNMP is used to configure the SNMP parameters for the unit Control Port Configuration Tab The control configuration window...

Страница 82: ...ot need DNS you can leave this field at 0 0 0 0 If your BBG 1090 DEC MPEG is connected to the Internet and you do not have a local DNS server a good option is the Google public DNS at 8 8 8 8 NTP Serv...

Страница 83: ...s the SNMP Read Write community string System Contact this configures the value for the MIB II System variable System Contact Whatever value entered here is returned for SNMP queries to that variable...

Страница 84: ...84...

Страница 85: ...connected devices being used as well as the connection network IP or ASI between the gateway and any other devices 3 The Technical Support information from the decoder itself This is downloaded from...

Отзывы: