Peripheral Interrupt Flag Bit Register EIF2
0xB2
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
EIF2
SPIIF
I2CIF
--
ADCIF
PWMIF
--
TF4
TF3
R/W
R
R
--
R/W
R
R/W
R/W
R/W
Reset value
0
0
0
0
0
0
0
0
Bit7
SPIIF:
SPI global interrupt indicator bit, read-only;
1=
SPI generates an interrupt, (this bit is automatically cleared after the specific interrupt flag is
cleared);
0=
The SPI did not produce an interrupt.
Bit6
I2CIF:
I2C global interrupt indicator bit, read-only;
1=
I2Cproduces an interrupt, which requires the software to clear (after clearing the specific interrupt
flag, this bit is automatically cleared);
0=
I2Cdid not produce an interrupt.
Bit5
--
Reserved, must be 0.
Bit4
ADCIF:
ADC interrupt flag bit;
1=
ADC conversion is completed, and software zeroing is required;
0=
The ADC conversion was not completed.
Bit3
PWMIF:
PWM global interrupt indicator bit, read-only;
1=
PWM generates an interrupt, (after the specific interrupt flag is cleared, this bit is automatically
cleared);
0=
The PWM did not produce an interrupt.
Bit2
--
Reserved, must be 0.
Bit1
TF4:
Timer4 timer overflow interrupt flag bit;
1=
Timer4 timer overflow, the hardware is automatically cleared when entering the interrupt service
program, and the software can also be cleared;
0=
The Timer4 timer has no overflow.
Bit0
TF3:
Timer3 timer overflow interrupt flag bit;
1=
Timer3 timer overflow, when entering the interrupt service program, the hardware is
automatically cleared, and the software can also be cleared;
0=
The Timer3 timer has no overflow.