ZL-GR6150-001-V1
Installation and Connection Instruction Manual
CMA (WUHU) Robotics Company Limited
37
between various internal components have been completed. After the installation and fixation of the
electric cabinet on the customer's site, the explosion-proof aviation plug-in cable can be connected to the
aviation plug interface reserved in the control cabinet. The test shall be conducted by relevant
professionals. Generally, there will be no wiring problems. If there are any related problems, the on-site
commissioning personnel can adjust or contact relevant technical personnel of CMA according to the
electrical schematic diagram delivered with the electric cabinet.
5.3 Cable and gas circuit connection of explosion proof cabinet
5.3.1 Explosion proof cable connection
The explosion-proof cabinet and the control cabinet are connected by aviation plug-in cable. After the
explosion-proof cabinet is installed and fixed at the customer's site, the explosion-proof aviation plug-in
cable can be connected to the reserved aviation plug-in interface of the control cabinet. The details are as
follows:
connection