Models DC-1, -10, -20B DC Spark Testers
DC-1, -10, -20B Instruction Manual
–
Page 32
Percent Load Limit (PLL)
This output will change state when the percent load reaches or exceeds the Percent
Load Limit PLLT.
See
the “Definition of Terms” section of the manual for more
information.
Percent Load Limit Threshold (PLLT)
Set as a percentage of the maximum current.
Fault Output Options
Fault Pulse (FPL)
This output will change state when a fault occurs.
See
the “
Definition of Terms
”
section of the manual for more information.
When fault pulse times are shorter than 50mS, timings may not be exact when
using relay type outputs.
Any Fault Alarm (AFA)
This output will operate in 3 different modes,
“NLC”
,
”LCH”
,
”RVF”
. The Any Fault
alarm is triggered by any high voltage fault that occurs.
See the “Definition of
Terms” section of the manual for more information.
Any Fault Alarm Mode (AFMO)
–
Non Latch Mode
The output will change state for the
configured “AFMS” time
.
–
Latch Mode
The output will change state until it is reset at the front panel or
remotely.
–
Remove Voltage on Fault
The output will change state and the test voltage will be
disabled until it is reset at the front panel or remotely.
Any Fault Alarm Time (AFMS)
Set in seconds (.01
–
5.0). If “AFMO” is set to “NLC”, this is the time
for
which the output will change state.
Содержание DC-1
Страница 2: ...Models DC 1 10 20B DC Spark Testers DC 1 10 20B Instruction Manual Page 1 Rev Null b0002 10 11 17 ...
Страница 7: ...Models DC 1 10 20B DC Spark Testers DC 1 10 20B Instruction Manual Page 6 Specifications ...
Страница 8: ...Models DC 1 10 20B DC Spark Testers DC 1 10 20B Instruction Manual Page 7 ...
Страница 58: ...Models DC 1 10 20B DC Spark Testers DC 1 10 20B Instruction Manual Page 57 ...