Models DC-1, -10, -20B DC Spark Testers
DC-1, -10, -20B Instruction Manual
–
Page 18
X3B to Spark Tester Connections
Conductor
Termi na l Bl ock
Connecti ons
Pi n
No.
Pi n
No.
Termi na l Bl ock
Connecti ons
Conductor
COM
10
9
Not Us ed
NC
COM
8
7
NO
6
5
NO
NC
5
4
COM
2
Des i gna ti on
4-Conductor
Ca bl e
Suppl i ed
wi th X3B (22
ga uge or
hi gher)
NO
NO
Fa
ul
t
R
el
ay
H
V
O
N
R
el
ay
To Spa rk Tes ter:
Wi re pi ns 10-7 to
s pa rk
tes ter pi ns 8-5 on the
s pa rk
tes ter termi na l bl ock
connector
GND
(3) 22 ga .
s tra nded
conductors
ra ted 250V,
l es s tha n
10 meters
i n l ength,
conta i ned
i n a
common
i ns ul a ti ng
s hea th
Spark Tester Terminal Block Connections
X3B Horn/Light Tower Terminal Block Connections
Not Us ed
(3) 22 ga .
s tra nded
conductors
ra ted 250V,
l es s tha n
10 meters
i n l ength,
conta i ned i n
a common
i ns ul a ti ng
s hea th
Fa
ul
t
R
el
ay
RESET
HV
ENABLE
8
6
Not Us ed
To X3A:
Wi re pi ns 8-5 to X3A
pi ns 10-7 on X3A termi -
na l bl ock connector
H
V
O
N
R
el
ay
(O
U
T0
)
Fa
ul
t
R
el
ay
(
O
U
T1
)
Des i gna ti on
COM
COM
4-conductor
ca bl e
s uppl i ed
wi th X3A
(22 ga uge or
hi gher)
9
7
**Switches and relays connected to pins 1,2, & 3
should be suitable for 24V low current
applications.
NO
22 ga .
s tra nded
conductors
ra ted 250V,
l es s tha n
10 meters
i n l ength,
conta i ned i n
a common
i ns ul a ti ng
s hea th
HV ON Indi ca ti on:
Dry rel a y conta ct pi ns
1&2 wi l l cl os e when
the tes t vol ta ge
exceeds 500v. For a n
i ndi ca ti on tha t HV i s
ON i n the el ectrode,
wi re a l a mp or
a uxi l i a ry devi ce* here.
H
V
O
N
R
el
ay
*When connecti ng a uxi l i a ry equi pment to dry rel a y
conta cts pi ns 1, 2, 3, 4, or 5, obs erve ma xi mum ra ti ngs of
120VAC a t 2 a mps or 240VAC a t 1 a mp.
Externa l Res et:
To res et the s pa rk tes ter fa ul t
rel a y wi th a n externa l s wi tch,
wi re a momenta ry s wi tch**
between pi ns 1&3. When
thes e conta cts cl os e, the fa ul t
rel a y wi l l return to a norma l
s ta te. The i nterva l tha t the
conta cts a re cl os ed mus t
exceed 50 ms .
HV Ena bl e:
CAUTION
For HV on the
el ectrode, i ns ta l l a norma l l y
cl os ed s wi tch or rel a y
conta ct** between pi ns 1&2.
Thi s s wi tch or rel a y s houl d
open a utoma ti ca l l y when the
wi rel i ne s top s wi tch i s
a cti va ted or be opened
ma nua l l y by the s ys tem
opera tor when the l i ne s tops .
FAILURE TO DO SO COULD
RESULT IN A FIRE HAZARD
If
the HV rema i ns ON i n the
el ectrode when your l i ne i s
s ta ti ona ry, the wi re
i ns ul a ti on i n the el ectrode
wi l l hea t a nd there i s a
da nger of combus ti on.
COM
NO
4
3
1
3
2
1
Process Control:
To activate external
lights,alarms or relays*
when a fault occurs, wire
them between dry relay
contact pins 5,4 & 3.
If the Lch function is ON
(set on the front panel),
the dry relay contacts will
remain closed until the
RESET button is pressed or
when pins 1&3 are closed
by remote switch
or relay. If the Lch
function is OFF, the dry
relay contacts will return
to normal state after the
interval known as the
PCd (Process Control
Duration, set on the front
panel) has elapsed.
Содержание DC-1
Страница 2: ...Models DC 1 10 20B DC Spark Testers DC 1 10 20B Instruction Manual Page 1 Rev Null b0002 10 11 17 ...
Страница 7: ...Models DC 1 10 20B DC Spark Testers DC 1 10 20B Instruction Manual Page 6 Specifications ...
Страница 8: ...Models DC 1 10 20B DC Spark Testers DC 1 10 20B Instruction Manual Page 7 ...
Страница 58: ...Models DC 1 10 20B DC Spark Testers DC 1 10 20B Instruction Manual Page 57 ...