48
6.2. CTC-1052-QT-DT35AW Programming Command Table
DTMF
CHARACTER
COMMANDS
DTMF
ACK
COMMAND OPERATION
TERM
I-
NATO
R
DTMF
ACK
DEFAULT
00#
Bi
To Set Caller ID (201-220)
Enter: Caller ID Se * + Caller ID
Note: Caller ID Sequence: 201-220
Symbol: *
Caller ID: maximum 20 digits
Example:
201*27912518
(201 represents that it
’s the
1
st
Caller ID; 27912518 represents the Caller ID)
#
Bi
Null
01#
Bi
Telephone number 1
(Used as Primary Medical Alarm number)
#
Bi
No number
02#
Bi
Telephone number 2
(Used as Secondary Medical Alarm number)
#
Bi
No number
03#
Bi
Telephone number 3
(Used as Primary Fire/CO2 Alarm number)
#
Bi
No number
04#
Bi
Telephone number 4
(Used as Secondary Fire/CO2 Alarm number)
#
Bi
No number
05#
Bi
Telephone number & GPRS/IP for alarm report
1=TEL1 , 2=TEL2 , 3=TEL3 , 4=TEL4,
5=GPRS1 , 6=GPRS2
#
Bi
1,2,3,4,5,6
06#
Bi
Telephone number
& GPRS/IP for status report
1=TEL1 , 2=TEL2 , 3=TEL3 , 4=TEL4,
5=GPRS1 , 6=GPRS2
#
Bi
5,6
10#
Bi
Global account number, 4 or 6 or 8 digits
#
Bi
No account number
11#
Bi
4 or 6 or 8 digits Account number 1 (Tel. Number 1)
#
Bi
No account number
12#
Bi
4 or 6 or 8 digits Account number 2 (Tel. Number 2)
#
Bi
No account number
13#
Bi
4 or 6 or 8 digits Account number 3 (Tel. Number 3)
#
Bi
No account number
14#
Bi
4 or 6 or 8 digits Account number 4 (Tel. Number 4)
#
Bi
No account number
20#
Bi
All formats the same,
3 = Speech, 4 = SMS CID
#
Bi
3=Speech
21#
Bi
3 = Speech, 4 = SMS CID
#
Bi
3=Speech
22#
Bi
3 = Speech, 4 = SMS CID
#
Bi
3=Speech
23#
Bi
3 = Speech, 4 = SMS CID
#
Bi
3=Speech
24#
Bi
3 = Speech, 4 = SMS CID
#
Bi
3=Speech
31#
Bi
Ringer enable, 0 = Disable, 1 = Enable
#
Bi
Ringer Disabled
32#
Bi
Audible fault alert, 0 = Off, 1 = On
#
Bi
Off
34#
Bi
Emergency button enable, 0 = Button off, 1 = Button
on
#
Bi
Emergency button
On
35#
Bi
Silent Mode, 0 = Silent mode On, 1 = Silent mode Off
#
Bi
Silent mode Off
37#
Bi
AC fault report, 0 = Off, 1 = On
#
Bi
On
38#
Bi
Follow-On & Call Back Function, 0 = Follow-On
(Reserved) , 1= Call-Back, 2= Follow-On & Call-Back
#
Bi
0 = Follow-On
40#
Bi
Set Access Code
#
Bi
1111
41#
Bi
Auto answer for Remote programming,
00 = call twice, 01 - 09 = Auto answer 1 - 9 rings
#
Bi
0
42#
Bi
Guard time delay for any compatible sensor (except
Fall Sensor), 00 = Instant reporting; … 99 = 99
seconds
#
Bi
10 seconds