Detector (SD) is pressed.
120 - Fall emergency
When Fall Sensor is triggered
147 - Sensor Supervisory Failure
When
CTC-1052-QT-DT35AW
is
unable to receive the signal transmitted
from the Wrist Transmitter for a pre-set
period by Command #49, the Green
LED will flash every 2 seconds.
154 - Water emergency
When Water Sensor (WS) is triggered
158 - Low temperature report
When temperature is below Low
Temperature Reporting Threshold
159 - High temperature report
When temperature is above High
Temperature Reporting Threshold
162 - Carbon Monoxide emergency /
Carbon Dioxide Alarm
When Carbon Monoxide Detector (CO)
is triggered
When the Test Button of Carbon
Monoxide Detector (CO) is pressed.
When
CO2
concentration
value
reaches or exceeds the Alarm
Reporting threshold.
301 - Panel AC Failure
When AC power fails for more than 10
sec, the Green LED flashes every sec
with a beep every 30 seconds.
302 - Panel Low battery
When CTC-1052-QT-DT35AW is under
Low Battery status, the Green LED
flashes every 2 seconds.
311 - Panel Battery Disconnection
When CTC-1052-QT-DT35AW is under
Battery Not Connected status, the
Green LED flashes every 2 seconds.
333 - No WTR Learnt-in
When CTC-1052-QT-DT35AW has no
WTR learned-in previously.
<NOTE>
This event code will be sent with a fixed
zone number of
072
339 - Medication Non-Adherence
When the scheduled-dose is still not
taken after “Time for Medicine” alarm
expires (default: 30 minutes).
341 - Medication Dispenser Mechanism
Jam
When the Medication Dispenser is
jammed (e.g. White T-Bar not in the
correct position).
342 - Medication Dispenser AC Fail
When AC Power for the Medication
Dispenser fails and lasts for 24 hours.
373 – Smoke/CO/CO2 Low Battery
When Smoke Detector (SD) / Carbon
Monoxide Detector (CO) / Carbon
Dioxide Detector (CO2) is under Low
Battery Status, the Green LED flashes
every 2 seconds.
380 – WTR / PB / FS Low Battery
When Wrist Transmitter (WTR), Panic
Button (PB), Fall Sensor (FS) is Low on
Battery, the Green LED flashes every 2
seconds.
383 - IR Tamper open
When the IR Tamper is opened.
384 - PIR Sensor (PIR) / Temperature
Sensor (TS) / Water Sensor (WS) Low
Battery
When PIR Sensor (PIR), Temperature
Sensor (TS), or Water Sensor (WS) is
Low on Battery, the Green LED flashes
every 2 seconds
601 – Manual trigger Test Report
When the Test Button is pressed, test
report is sent to monitoring center.
602 - Periodic Test Report
When CTC-1052-QT-DT35AW reports
Periodic test call to monitoring Center.
606 - Follow-On Function
When CTC-1052-QT-DT35AW receives
kiss-off from Monitoring Center for
opening Speech channel.
611 - Global test
When CTC-1052-QT-DT35AW reports
Global Test to Monitoring Center.