43# Periodic Test Call:
-
CTC-1052-QT-DT35AW can be programmed to make test calls periodically (every 0 – 7 days,
0-23 hours, and 0-59 mins). Whenever programming mode is accessed, CTC-1052-QT-
DT35AW will reset the Periodic Test Call timer.
-
Whe this function is disabled (0 day, 0 hour, 0 min), CTC-1052-QT-DT35AW will not make
periodic test calls.
44# Mobility Timer:
-
This function monitors user movement around the premises and sends an inactivity report to
the Monitoring Center if the user fails to reset the inactivity timer.
-
Mobility Timer can be selected as 1-36 HR count down periods, or it can be disabled.
-
The Mobility Timer counting down can be reset by either pressing the RESET button on CTC-
1052-QT-DT35AW, or movement detected by PIR Detector.
46# Two way Period:
-
This is used to program the allowable time duration for Two-way voice communication period
(Speech mode). It can be set from 1 to 10 minutes.
47# Off-Set Time:
-
After power is supplied or re-supplied to the Control Panel, the first auto check-in report will be
made according to Offset Period setting. This is used to test whether the CMS is able to
receive the report from the Panel accurately.
-
After this test report is sent, the Control Panel will then send reports at regular interval based
on the setting of the
Periodic Test Call
.
49# Supervision:
-
This option is used to enable system Supervision function. Once enabled, CTC-1052-QT-
DT35AW will be able to receive the check-in signals from Wrist Pendants (WTR) to indicate
their proper functioning.
-
When the supervisory timer expires and no supervision signal is received from WTR, CTC-
1052-QT-DT35AW will send a Supervisory Failure report.
53# Voice Prompt Language:
-
Select the voice prompt language for CTC-1052-QT-DT35AW. Available options include
English and beep only.
54# Fall Sensor Sensitivity
-
Select the Fall Sensor 3 Sensitivity. There are 5 sensitivity levels for selection. 1=Lowest
Sensitivity, 5=Highest Sensitivity.
#63 Set Speaker Volume
-
To set the speaker volume with a number, ranging 1 to 5. The higher the value, the louder the
voice.
#64 Set Microphone Sensitivity
-
To set the microphone sensitivity with a number, ranging 1 to 5. This value represents the
received sound source range. The higher the value, the wider range of sound source.
66# Guard Time Delay for Fall Sensor:
-
The Guard Time for Fall Sensor’s fall detection function is set separately from regular Guard