13
any DTMF key except the hang up key to
reset the communication time to its preset
duration.
Command 47
Off-Set Time
After the Control Panel‘s power is supplied,
the time of the Check-in Report starts
calculating.
According to the setting of Off-Set Time, the
Control Panel will send Check-in Report
once, and then send report according to the
setting of Command 43
-
Test call.
Function
Selection
Result
(1)
1 Hour
(2)
2 Hour
(3)
3 Hour
(4)
4 Hour
(5)
8 Hour
(6)
12Hour
Factory default is set as (
1
) 1 Hour. When
the
Off-Set Time
is reset in programming
Mode, the time of the Off-Set period will
recalculate.
Off-Set time Report will be sent only once,
and then the Control Panel sends Check-in
Report according to setting of period test
call, unless the Control Panel restarts or the
Off-Set time is reset.
<NOTE>
Whenever
programming
mode
is
accessed, CTC-1052-QT-DT35AW will
reset the Off-Set timer.
Command 49
Supervision
This option is used to enable system
Supervision function. Once enabled, CTC-
1052-QT-DT35AW will be able to receive
the check-in signals from Wrist Pendants
(WTR) to indicate their proper functioning.
Function
Selection
Result
(0)
Disable
(1)
4 Days
(2)
5 Days
(3)
6 Days
(4)
7 Days
(5)
8 Days
(6)
9 Days
(7)
10 Days
Factory default is set as (
0
)
Disable
. No
code is sent to Monitoring Center.
When the supervisory timer expires and no
supervision signal is received from WTR ,
CTC-1052-QT-DT35AW
will
send
a
Supervisory Failure
report.
Supervisory Failure
is a status report.
Command 53
Voice Prompt Language
This command is used to set voice prompt
language.
Function
Selection
Result
(0)
English
(1)
Arabic (Reserved)
(2)
Spanish (Reserved)
(3)
Russian (Reserved)
(19)
Other (Reserved)
(20)
Beep
Factory default is set as (
0
)
English
.
Command 54
Fall Sensor Sensitivity
This command is used to set Fall Sensor
Sensitivity.
There are 5 sensitivity levels for selection.
1=Lowest Sensitivity, 5=Highest Sensitivity
Function
Selection
Result